1-5-37
(3) Detaching and refitting the drum separation claws
Follow the procedure below to replace the drum separation claws.
Procedure
1. Remove the drum unit (see page 1-5-37).
2. Remove two screws and remove the lower
cleaning seal.
Figure 1-5-68
3. Release the inserted parts and remove the
drum separation claws.
4. Replace the drum separation claws and
Install the claws.
5. Refit all the removed parts.
Figure 1-5-69
Screw
Screw
Lower
cleaning seal
Drum
separation claw
Drum
separation
claw
Drum
separation
claw
Drum
separation
claw
Drum
separation
claw
Drum separation claw
Inserted part
Lower
cleaning seal
Lower cleaning seal