![Olivetti BF1 Скачать руководство пользователя страница 69](http://html1.mh-extra.com/html/olivetti/bf1/bf1_service-manual_731778069.webp)
3H3
1-4-16
(9)
The rear stapler
motor does not oper-
ate.
Poor contact in the rear sta-
pler motor connector termi-
nals.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Broken rear stapler motor
gear.
Check visually and replace the rear stapler motor gear if neces-
sary.
Defective rear stapler
motor.
If the rear stapler motor dose not operate when 5 V DC is output
to YC18-A17 on the finisher main PWB, replace the rear stapler
motor.
Defective finisher main
PWB.
If 5 V DC is not output from YC18-A17 on the finisher main PWB,
replace the finisher main PWB.
(10)
The front clincher
motor does not oper-
ate.
Poor contact in the front
clincher motor connector
terminals.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Broken front clincher motor
gear.
Check visually and replace the front clincher motor gear if neces-
sary.
Defective front clincher
motor.
If the front clincher motor dose not operate when 5 V DC is output
to YC18-B2 on the finisher main PWB, replace the front clincher
motor.
Defective finisher main
PWB.
If 5 V DC is not output from YC18-B2 on the finisher main PWB,
replace the finisher main PWB.
(11)
The rear clincher
motor does not oper-
ate.
Poor contact in the rear
clincher motor connector
terminals.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Broken rear clincher motor
gear.
Check visually and replace the rear clincher motor gear if neces-
sary.
Defective rear clincher
motor.
If the rear clincher motor dose not operate when 5 V DC is output
to YC18-A25 on the finisher main PWB, replace the rear clincher
motor.
Defective finisher main
PWB.
If 5 V DC is not output from YC18-A25 on the finisher main PWB,
replace the finisher main PWB.
(12)
The paper entry
motor does not oper-
ate.
Poor contact in the paper
entry motor connector ter-
minals.
Reinsert the connector. Also check for continuity within the con-
nector cable. If none, remedy or replace the cable.
Broken paper entry motor
gear.
Check visually and replace the paper entry motor gear if neces-
sary.
Defective paper entry
motor.
Run maintenance item U240 and check if the paper entry motor
operates when YC12-1, YC12-3, YC12-4 and YC12-6 on the fin-
isher drive PWB go low. If not, replace the paper entry motor.
Defective finisher drive
PWB.
Run maintenance item U240 and check if YC12-1, YC12-3, YC12-
4 and YC12-6 on the finisher drive PWB go low. If not, replace the
finisher drive PWB.
Defective finisher main
PWB.
Run maintenance item U240 and check if YC25-12 on the finisher
main PWB goes low. If not, replace the finisher main PWB.
Problem
Causes
Check procedures/corrective measures
Service Manual Y1043
71
-
8
Содержание BF1
Страница 1: ...Option Copier SERVICE MANUAL Code Y104371 8 DF 650 MT 1 A BF1 A PH 4A PH 4C...
Страница 3: ...This page is intentionally left blank...
Страница 9: ...This page is intentionally left blank...
Страница 160: ...UPDATING STATUS DATE UPDATED PAGES PAGES CODE 12 2008 1ST EDITION 160 Y104371 8...