MAX OPERATING PRESSURE:
..............................................................5 bar (500kPa)
RECOMMENDED OPERATION PRESSURE:
..........................................1.5-5 bar (150-500kPa)
MAX HOT WATER TEMPERATURE:
.....................................................65°C
RECOMMENDED HOT WATER TEMPERATURE:
..................................50°C
Paris Wall Spout
PA102200CR/PA102206MB/PA102200BN
Where water pressure exceeds 500kPa, a pressure reducing device is required to be installed. Note that
water pressure overnight can reach 150% of the daytime pressure.
CARE & MAINTENANCE
THIS BASIN/BATH SPOUT MUST BE INSTALLED BY A LICENSED PLUMBER IN
ACCORDANCE WITH LOCAL REGULATIONS
This Oliveri tap is manufactured to standard AS/NZS 3718.
Note: - Copper tube pieces, sand, dirt or stones
- Thread tape
- Other objects not normally present in potable water supplies.
Technical Data
Installation Instructions
PA102200CR/PA102206MB/PA102200BN installation instructions.pdf
Clean with a soft cloth and warm soapy water as necessary - rinse and dry after cleaning. Under No
Circumstances should abrasive or acid based cleaning products be used
.
WARRANTY
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are
entitled to a replacement or refund for a major failure and for compensation for any other reasonably
foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to
be of acceptable quality and the failure does not amount to a major failure.
SERVICE
If a warranty service agent finds that the spout is not at fault, T2 Services Pty Ltd reserves the right to
pass on any callout fee to the householder.
Issue Date 30/11/2018 Revision Number: V1.0
This basin/bath spout is warranted to be free from manufacturing defects for a period of 10 Years
:
10 years for body,
5 years for seals, tails, fittings and aerators, 1 year for finish and labour, when used in a domestic situation.
This warranty does not cover against normal wear and will be voided if the product is misused or
not installed in accordance with these instructions.
Note: Fitting spout-attached devices, including water
filters, to this spout will void warranty.
If the Plumber / Installer is satisfied that the problem is not due to poor installation, contact T2 Services Pty Ltd
for assistance on:
Note: Installation of aerators containing flow regulators.
Upon re-installation, the aerator should be tightened with an aerator key to prevent removal by hand.
Before attempting any work involving mains water supply lines, ensure the water supply is shut off.
This basin/bath spout must be installed in accordance with these instructions.
If the problem represents a danger, or damage to property may occur, immediately shut off the water
supply. If the spout requires servicing, please contact your plumber (preferably the one who installed
it). Most problems occur due to contaminated supply lines or water pressure exceeding 500KPa.
Unscrew and clean the spout aerator periodically - especially if you notice a drop in water pressure.
Note: Warranty claims will not be honoured where the spout has malfunctioned due to
the presence in the water supply of ;
In the event this product is rendered obsolete and a replacement product is required, Oliveri Solutions Pty Ltd
reserves the right to supply a product of equal substitution at their discretion.
Ph: (07) 55960738
Fax: (07) 55273353
Email: [email protected]
https: //oliveri.com.au/service-and-warranty