SHERPA SHW
Sanitary water heat pump
21
parameter checking. Select the parameter by pressing
or button. Press
to exit.
2)
When the unit is ‘OFF’ (not on clock and timer setting status), press
and
buttons together for 2” and insert the
password confirming each field with
button to entry the installer parameter setting. Select the parameter by
pressing
or and short press
button to access the parameter value. Press
or button to adjust the value
and confirm with
button. Press
to exit.
For example: parameter 01, the relating value is 5°C:
Once the parameters have been set; the user cannot change the parameters optionally. Please ask a qualified
service person to do this when required.
-
By pressing and buttons at the same time and hold for 5 seconds, the buttons are locked.
-
By pressing and buttons at the same time and hold for 5 seconds again, the buttons are unlocked.
4.
and
buttons
Clock setting:
-
Press
button to entry the clock setting interface: hour icon “
88
:88” flashes;
-
Press the and buttons to set the exact hour(s) and press
to confirm: minute icon “88:
88
” flashes;
-
Press the and buttons to set the exact minute(s) and press
to confirm and exit.
The set clock time is displayed.
Timer setting:
-
Press
button for 5” to entry the timer setting interface: timer ‘ON’ hour icon “
88
:88” flashes;
-
Press the and buttons to set the exact hour(s) and press
to confirm: timer ‘ON’ minute icon “88:
88
” flashes;
-
Press the and buttons to set the exact minute(s) and press
to confirm: timer ‘OFF’ hour icon “
88
:88” flashes;
-
Press the and buttons to set the exact hour(s) and press
to confirm: timer ‘OFF’ minute icon “88:
88
” flashes;
-
Press the and buttons to set the exact minute(s) and press
to confirm.
Timer ‘ON’ and timer ‘OFF’ icons are displayed near the clock time.
Press
button to cancel the timer settings during the timer ‘ON’ and timer ‘OFF’ programming, returning in this way to clock
time visualization.
The timer settings are repeating and are still valid after a sudden power cut.
5.
button
Press this button to turn ‘ON’ or turn ‘OFF’ the electrical heater.
The electrical heater will work according to the control
program.
When the unit is ‘ON’, press this button for 5” to enable or disable the fan ventilation function.
6.
Error codes
During standby or running status, if there is a malfunction, the unit will stop automatically and show the error code on the
right screen of the controller.