MAESTRO SMART
45
10.1.4
Technical data
10.1.4.1 Position of the connecting cable
Connect the communication cable from the kit to connector CN
1
.
10.1.4.2 Selection of the interface installation position
The compartment in which the B101
8
board is housed is in the upper
right.
– Disconnect the electrical power from the climate control unit.
– Remove the unit from the wall bracket.
– Loosen the body (Cf. 9.2 Body removal, on p. 32) in order to access
the housing (A) of the board.
– Remove the screws (1) and the cover (2).
– Mount the B101
8
board in its housing using the proper screws (3).
– Connect the communication cable to the serial port (4) located at the
bottom
of the unit.