Page 3 from 3
In recess mounting installation the
required opening is 280 x 50 mm.
The material must withstand the
luminaires weight.
280
50
Placing the mounting springs
Α-3018
1
2
Place one part of the mounting spring
first and then the other one.
Place the edges of the mounting spring
as shown in picture.
1
2
Recess mounting
in
suspended ceiling
A-3018
Mounting springs
for recess mounting
A-3018 mounting springs
Ceiling mounting
Wall mounting
Mounting methods
When the device is mounted externally it can use the A-1028 mounting box.
NOTE:
LED= Light Emitting Diode
LABELING EXPLANATION:
X: Self contained
1: Maintained (*)
A: Including test device
180: 3 hour duration
922044006_09_0
20
(*)
Maintained operation: The luminaire lights its illumination source, when it is powered by the mains
power supply or not
.
Non-Maintained operation: The luminaire lights its illumination source,
only in power supply’s failure.
In case that the led strip must be replaced to ensure lumen output LED module can be
replaced only by a competent personnel.