background image

4

 

Electrical

 

Connections

1

9

4.1

6

 

Wireless

 

push

 

buttons

 

settings

1. To d

elete

:

P

ress

 the

 "encode"button

 

until

 the 

buzzer

 

sound

 ceases,then rel

ease

 

the

"encode"button.

2. To pair

:

Press 

the 

"encode"button  once

-the 

buzzer

 will sound. N

ow press  the

"

PRESS

"

 

button ,the  buzzer

 sound will cease

,indicat

ing

  

that 

the  code  

has

successfully

 

been 

learned.When

 you use

 the  remote control,the  buzzer  will  sound

for  2 seconds.

3.

Note:

If

  you  

press

  the  

"

PRESS

"

  button,

and if 

the  buzzer

 sounds twice-this is

indicating that the learning processes has failed

, please  

repeat step 2 again

.

The wireless push button need to encoded with the door opener

 

Steps:

Olide

Содержание 120B

Страница 1: ...the Open Close stopping points will occur after the initial hardware installation An uninstalled unit will result in constant motor rotation For support please email us tech olideautodoor com INSTALL...

Страница 2: ...ctions for magnetic locks 15 4 9 Connections for electric locks 15 4 10 Connection with the touchless hand sensor switches 15 4 15 Double door synchronous settings 18 4 16 Wireless push buttons settin...

Страница 3: ...ees Hold Open Time 1 30 sec Adjustable Max Door Frame Depth Door Width Max 1200mm 47 2 Max Opening Angle 450mm 17 7 Min 660mm 26 120 degrees Environment Temperature 20C to 50C 4F to 122F Protection Cl...

Страница 4: ...Option for inswing opening Push Arm Option for outswing opening 2 Sensor cable hole Motor Assembly Cover Plate Base Plate Power cable hole Pull Arm Option for frameless glass inswing opening Push arm...

Страница 5: ...tion 3 1 Installation example Pull Arm The door opens to the inside toward the unit using the pull arm assembly Push Arm The door opens to the outside away from the unit using the push arm assembly 3...

Страница 6: ...the frame with eight wood screws or eight M6 15 countersunk screws Please note that 20mm sensor cable hole is always to the right side and that the power cable access is always to the left The sensor...

Страница 7: ...eft hand installation At door right 240 9 44 240 9 44 20 160 6 3 Fix the slide rail of pull arm on the door panel as shown using three round head wood Screws if the door panel is steel please use M6 1...

Страница 8: ...ccording to the door depth L until the angle between the push arm and the door panel is 90 At door right 6 50 1 96 290 11 42 Fix the support holder of push arm on the door panel as shown using two rou...

Страница 9: ...3 Installation 7 3 4 Installation of Push arm Stop screw Adjust the stop screw position slotted hole to allow full opening of the door Do not exceed 90 O l i d e...

Страница 10: ...or 8 Clasp the door with door clamp tightly then fix the clamp with M5 8 Hexagon socket set screws M5 8 Set screws M5 8 Set screws Please connect the push arm to the door clamp with the M5 8 Hexagon s...

Страница 11: ...on 3 6 Installation of Pull arm for frameless glass door 9 Clasp the door with door clamp tightly then fix the clamp with M5 8 Hexagon socket set screws M5 8 Set screws Connect the pull arm to the mot...

Страница 12: ...3 Installation 10 3 7 Installation of operation system Hook the component assembly onto the base plate as shown Attach it with 8 allen head screws 3 8 Installation of Cover Opening the cover O l i d e...

Страница 13: ...3 Installation 11 3 9 Connect pull arm to the operation system 3 10 Connect the push arm to the operation system M M Motor output shaft O l i d e...

Страница 14: ...12 4 4 Electrical Connections Control panel details 4 1 Connecting with keypads Power wiring Please connect the 110V 240V AC power input according the left picture O l i d e...

Страница 15: ...4 Electrical Connections 4 13 4 2 connecting to microwave sensors 4 3 connecting to PIR sensors 4 4 Connecting to safety motion top scans O l i d e...

Страница 16: ...4 Electrical Connections 4 14 4 5 Connecting to plastic push buttons 4 6 Connecting to wiring disabled push buttons 4 7 Connecting to wireless handicapped push buttons O l i d e...

Страница 17: ...tton on the keychain remote control to initialize for it It will work normally afterwards 4 9 Connecting to electrcal locks Important Notes As maglocks need constant power You will need to press the L...

Страница 18: ...g to wireless touchless sensor switch Olide 508 Olide 512 4 12 Connecting to wired touchless sensor switch Olide 514 Olide 513 and Olide 513N 4 13 Connecting to wired touchless sensor switch Olide 514...

Страница 19: ...4 Electrical Connections 4 14 Connecting to wired narrow handicap push button 515 17 O l i d e...

Страница 20: ...r COM COM safety sesnsor close safety sensor close safety sensor open safety sensor open interlock input interlock input COM COM interlock output Please use the hand programmer for setting the double...

Страница 21: ...sound Now press the PRESS button the buzzer sound will cease indicating that the code has successfully been learned When you use the remote control the buzzer will sound for 2 seconds 3 Note If you p...

Страница 22: ...2 To pair Hold the Encode button until the buzzer sounds Then press any button on the remote control The buzzer should silence meaning that encoding process is complete 3 If successful when the remote...

Страница 23: ...er slave cs closing speed n3 synchronize settings cd closing low speed angle o manual open door settings jb closing force L lock mode selection ok opening hold time F open direction settings P door cl...

Страница 24: ...5 Parameters Adjustment 22 5 2 adjustment steps manual push force adjust Note If you want to adjust the manual push force for push go function just adjust the closing force accordingly O l i d e...

Страница 25: ...change the opening direction using the Handheld Programmer The door constantly rebounds when closing and repeatedly tries to open and close Check for obstacles in the path of travel of the door clear...