OleumTech Wio BR-0900-RM4 Скачать руководство пользователя страница 1

 

 

 

  

 

 

 

 

 

 

 

 

Radio Kit with Onboard I/O 

User Guide 

Version 80-7059-001_E

 

 

Model Numbers 

BR-0900-RM4 | BR-0915-RM4 | BR-2400-RM4 

 
 
 

Содержание Wio BR-0900-RM4

Страница 1: ...Radio Kit with Onboard I O User Guide Version 80 7059 001_E Model Numbers BR 0900 RM4 BR 0915 RM4 BR 2400 RM4...

Страница 2: ...SYSTEM OVERVIEW 4 4 SIGNAL CHAIN DIAGRAM 5 5 HARDWARE AT A GLANCE 6 6 RF DIAGNOSTICS AND TRANSMISSION SPEED 7 7 DIP SWITCH FUNCTIONS 8 8 RF SETUP BEST PRACTICES 13 9 INSTALLATION 14 10 WIRING DIAGRAM...

Страница 3: ...T install or mount on an application with high vibration WARNING The WIO System must be installed within an enclosure that requires a tool to access This is to prevent inadvertent disconnection of any...

Страница 4: ...in accordance with the instructions may cause harmful communications to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipm...

Страница 5: ...channels that can be set up for the signals to travel in either direction Module A to B or B to A For the sake of simplicity and ease of use the I O count in this system is fixed non expandable The RM...

Страница 6: ...A Analog signals travel only in one direction from Radio A to Radio B B Digital Discrete Programmable I O PIO The direction of digital signals are programmable by channel meaning they can travel in ei...

Страница 7: ...Radio Kit with Onboard I O User Guide 6 5 HARDWARE AT A GLANCE...

Страница 8: ...When left LED is yellow it requires attention i Flashing yellow indicate a weak RF signal worse than 94 dB ii Solid yellow indicates RF failure 1 Triggered when RF communication is lost for 10 consecu...

Страница 9: ...ult Radio A Inputs Radio B Outputs ii The system supports any combination of signal directions RADIO A RADIO B t Please note that DIP Switch Input Output positions are reversed on Radio A and B 2 Sign...

Страница 10: ...adio Module will automatically place the outputs to user configured fail safe states RADIO A RADIO B 2 How to Monitoring RF Health using a PIO channel i To continuously monitor RF health of the system...

Страница 11: ...Radio B only Controlled by DIP Switches 4 and 5 2 When Radio communication is lost for 10 seconds or more the Radio Module will automatically place the outputs to user configured fail safe values RAD...

Страница 12: ...900 MHz Only 1 900 MHz only Controlled by DIP Switch 6 2 140 mW default or 1 W option 3 Transmit power setting must match on both Radio Modules RADIO A RADIO B 4 2 4 GHz system s transmit power is fi...

Страница 13: ...Radio Modules 2 900 MHz controlled by DIP Switches 7 and 8 channels 0 to 3 RADIO A RADIO B 3 2 4 GHz controlled by DIP Switches 6 7 and 8 channels 0 to 7 RADIO A RADIO B 4 Examples of how to select R...

Страница 14: ...other solid obstructions for improving RF signal quality 5 Install antennas at least 10 ft above ground when possible 6 When using directional antennas be sure to point the antennas at each other and...

Страница 15: ...urvey prior to installation is highly recommended There are various types of antennas including bulkhead omni and yagi Please use the appropriate type for your application 6 Connect Antenna to Radio M...

Страница 16: ...board I O User Guide 15 B How to Detach Radio Module from DIN Rail WIO Radio Module can be removed from the din rail by inserting the tip of a flathead screwdriver into removal slot located on the met...

Страница 17: ...ty protection 1 To reset the device you can power cycle the device or press and hold Tx button down for 4 seconds until the LEDs are extinguished 2 Device must be reset after modifying any DIP switch...

Страница 18: ...Radio Kit with Onboard I O User Guide 17 B Analog 4 20 mA Input Radio A only z...

Страница 19: ...Radio Kit with Onboard I O User Guide 18 C Analog 4 20 mA Output Wiring Radio B only...

Страница 20: ...9 D Digital Discrete Input Wiring 1 The PIO DIP switch must be set to Input Accepts Dry Contact Internal 3 3 Vdc Pull Up Open Drain NPN and Voltage Level Output 0 30 Vdc Max Input Voltage Threshold Si...

Страница 21: ...t Wiring i The PIO DIP switch must be set to Output Open Drain NPN Outputs Inductive Load Sink Current 1 Amp 30 Vdc Max Voltage Level Output Internal Pull Up Signal H Vo 3 3 Vdc Signal L Vo 0 2 Vdc Ac...

Страница 22: ...ng Weight Single 0 5 lbs 227 g Double 0 8 lbs 363 g Net Weight Single Radio 0 3 lbs 136 g Warranty 2 Year Limited B Radio Features Communication Type Point to Point Wireless I O Communication System R...

Страница 23: ...al H Vi 1 85 Vdc Signal L Vi 1 03 Vdc Output Rating Inductive Load Sink Current 1 Amp 30 Vdc Max Internal Pull Up Signal H Vo 3 3 Vdc Signal L Vo 0 2 Vdc Voltage Level Output Accepts Optional Ext Pull...

Страница 24: ...s locations D Equipment has only been tested for electrical safety No evaluation of functional safety and performance characteristics has been conducted E This is OPEN type equipment that must be inst...

Страница 25: ...that the goods or systems or any part thereof are i misused abused or otherwise damaged ii repaired altered or modified without OleumTech s consent iii not installed maintained and operated in strict...

Страница 26: ...8586 949 305 9009 Fax 949 305 9010 https oleumtech com https wio oleumtech com OleumTech has made a good faith effort to ensure the accuracy of the information in this document and disclaims the impl...

Отзывы: