Operating Modes
49
7.2.1 New Scan
After activating this operating mode you have the possibility to adjust certain settings. There are
different parameters which influence the measurement. In figure 7.4 you can see the corresponding
submenu.
You can modify the following parameters (the underlined values correspond to the setting made
by the factory):
•
Impulse Mode (Automatic, Manual)
If you are working in the Manual mode the measured values will only be recorded when using
the joystick or by pushing on the start button. If you select the Automatic mode, the measured
values will be recorded represented on the display continuously.
•
Impulses (Auto, 10, 20, ..., 50)
Number of measured values per search line. If you select "Auto" the number of impulses can be
adapted to the current length of your search line. During the first line the device will read values
regulary without stopping. When you want to finish your first line you have to press the
OK
key,
to stop the measuring process of the current line. The device will store the number of impulses
and use it for all further scan lines on the same scan. By selecting the value 10, 20, ... or 50 you
can preset the number of impulses you need in one measured line.
OKM Ortungstechnik GmbH
Illustration 7.3: Ground Scan – Submenu
Illustration 7.4: Ground Scan – Parameter