background image

Fig.7

Fig.8

Fig.8-1

Fig.9

4, Cares Before Installation Valve To Piping

Installation place :

Application to heavy-vibrant positions to be avoided.  
To keep enough space for maintenance work.  (Fig.7)

lInstallation work :

Connect the valve and the piping flanges correctly. 
Forcing the valve to insert between the piping flanges 
to be avoided.

Gasket packing :

The insertion between the valve and the piping-flanges 
shall be needed the gaskets.  In inserting,adjust 
both the valve and the gasket to the center of the 
flanges accurately. Keep space of about 3mm to 5mm 
between the valve to the piping-gasket (the flanges) on 
each side.  (Fig.8)
Do not insert the valve between the piping flanges 
forcefully.  And also, do not use the flexible material 
such as rubber to the gasket, otherwise, we 
recommend the joint seat as the piping-gasket.  
Further, in using the special gasket such as the spiral 
gasket, please contact to sales person in charge.

Disc position :

Keep the valve in closed position when installation to 
the pipings.

Installation the valve to ab ent pipe :

Upon installation of the valve to the pipings, no define 
limitation of direction of the valve being installed but, 
under such condition as illustrated in Fig.8-1, direction 
of stem to be cared.

Installation the valve to a return valve to a return valve, etc... :

When the valve to be installed directly to return valve, 
pumps, etc…, there may be cases in which disc 
touches to other upon its full opening. In this case, 
short-pipe to be fixed before installation of the valve. 
(Fig.9) 

6

Содержание 5410 Series

Страница 1: ......

Страница 2: ...2 personal injury means an injury without hospitalization or long term hospital visit for medical treatment Types of indications are explained below This symbol indicates the prohibition items which...

Страница 3: ...2...

Страница 4: ...3...

Страница 5: ...apse of package s to be avoided Upon carriage valve to be nicely loaded so that any collapse to valve could be avoided When valve to be carried after removing packing excessive force to valve to be av...

Страница 6: ...keeping the valve installed to pipings to be avoided Fig 6 Make sure welding work is completely done before installation the valve to the piping Flanges to check and confirm on deflection or miscenter...

Страница 7: ...e piping flanges forcefully And also do not use the flexible material such as rubber to the gasket otherwise we recommend the joint seat as the piping gasket Further in using the special gasket such a...

Страница 8: ...the flange holes to suspend the valve then center the valve to the flanges accurately 7 Tighten up bolts Firstly as Fig 10 1 top and bottom tighten the bottom of the bolt A and B not to drop the valv...

Страница 9: ...rn the hand wheel with a wrench or lever in order not to cause trouble Fig 12 Do not use blank flange Keep the valve fully opened while pressure test etc Do not use the fully closed valve as a blind f...

Страница 10: ...of the problem Please see the trouble shooting chart shown in P 15 2 Removal From Pipings Warning Check pressure inside pipings before removing the valve from pipings When the valve removes from pipin...

Страница 11: ...10...

Страница 12: ...11...

Страница 13: ...12...

Страница 14: ...and then holdit up and remove it 3 Removing the Indicator Remove two bolts fixes up the indicator And then strike the pin sets the indicator by the plastic hummer and remove the pin and the indicator...

Страница 15: ...Gear operation type Fig 26 1 Check the disc position Open the valve fully 2 Removing the actuator Keep the valve fully opened by turning the handwheel 3 Set the actuator Connect and fix the gear opera...

Страница 16: ...15...

Страница 17: ...16...

Страница 18: ...17...

Страница 19: ...18...

Страница 20: ...0 Ikeshita Chikusa ku Nagoya shi Aichi 464 0067 Japan Phone 81 52 752 8831 Fax 81 52 752 8833 Hiroshima Sales Office Otemachi Chuo Building 3F 3 8 1 Otemachi Naka ku Hiroshima shi Hiroshima 730 0051 J...

Отзывы: