5
RS485 CONNECTION
The 360° camera is set in protocol PELCO-D and baud rate 9600.
User can use keyboard, DVR or any RS485 device to control 360° camera.
Ex: keyboard
How to setup connection between keyboard and camera
Press MENU button of keyboard for function setup
Using direction key to select system menu and then press ENTER to get in.
Follow below setting and ready to control camera with command.
1. Keyboard ID Setup: Press ENT -- > Press 1
Press ENT
Esc
2. Master Setup:
Press ENT -- > Press 1
Press ENT
Esc
3. CAM Type Setup: Press ENT -- > Choose protocol 5: PELCO-D
Press ENT
Esc
4. Baud Rate Setup: Press ENT -- > Choose Baud Rate 1:9600
Press ENT
Esc
5. Press “ESC” to exit menu.
Note: If you are using others keyboard brand, please make sure the protocol setting is on PELCO-D and baud
rate 9600. And the control command is same as usual.
Command:
The screen mode default is on mode 5. It displays in 5 windows (quad + 360°).
Camera 1 ~ 4 is virtual split from 360° screen. User can control camera 1~4 like PTZ dome to do
up/down/left/right movement.
Control on screen in mode 5,
1.
Press 1 + CAM to call camera 1 and after to use joystick to move.
2.
Press 2 + CAM to call camera 2 and after to use joystick to move.
3.
Press 3 + CAM to call camera 3 and after to use joystick to move.
4.
Press 4 + CAM to call camera 4 and after to use joystick to move.
Recommended Keyboard Controller for Setting
Economical 2-Axis Keyboard Controller
PTZ-KB050
3-Axis Keyboard Controller
PTZ-KB050X
3-Axis Keyboard controller
PTZ-KB250X
RS485 port
RS485 port 1
RJ11 Pin 3+, Pin -
RS485 cable
Positive
White - Negative
1. Keyboard ID Setup
2. Master Setup
3. CAM Type Setup
4. Baud Rate Setup
CAM: 001 < MUX: 00 DV: 00
Setup Menu
> System Menu
CAM Menu