![OKIDATA B6300 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/okidata/b6300/b6300_remanufacturing-instructions_3620283005.webp)
UNINET IMAGING INC.
•
OKIDATA
®
B6300 REMANUFACTURING INSTRUCTIONS
30. Reinstall the wiper blade back into position with the two gold-colored screws as shown.
31. Reinsert the PCR into the clips by using
slight force.
36. Remove the end-cap on the gear-side of the toner cartridge by first removing two gold-
colored screws as shown.
35. You are now ready to disassemble the
toner cartridge
33. Reinstall the remaining drum holder on
the opposite side.
32. Reinsert the OPC gear side first.
34. Line up the drum pin and screw back
into place.
11124 Washington Blvd., Culver City, California U.S.A. 90232 Ph: 310 280-9620 • Fx: 310 838-7294 • [email protected]
© 2005 Uninet Imaging Inc. All Trademark names are property of their respective owners. Product brand names mentioned are intended to show compatibility only. Uninet Imaging does not guarantee or warrant downloaded information.
USA
+310-280-9620
+310-838-7294
Ph:
Fx:
JAPAN
+81-3-44-55-2789
+310-838-7294
EUROPE
+34-93-757-1335
+34-93-741-4166
BRAZIL
+55-11-4822-3033
+55-11-4822-3353
ARGENTINA
+54-11-4574-3706
+54-11-4574-3706
www.
u n i n e t
imaging.com