Cabling Systems & Solutions
UTP = Unshielded Twisted Pair
Rev092007 VG01
If your RJ45 connector is plastic housing (unshielded), then the cable connection must do the
following:
1.
The ground cable must pull out around 5-10cm length to connect with VGA Extender’s ground screw for
grounding.
2.
Make the ground cable connect to ground screw, then plug RJ45 connector.
Installation:
CAUTION:
Make sure to follow this instruction for DIP switch setting when using
CAT5 UTP cable
. Please
disconnect the wiring from the receiver to monitor when the picture is not normal, otherwise it may damage your
monitor. To have the best picture and quick installation, please use STP cable. There is no need to adjust Dip
switch when using STP (shielding twisted pair) cable.
* There is no need to adjust Dip switch when using STP (shielding twisted pair) cable.
* Follow setup below for Dip Switch setting when using with UTP cable.
1. Set up the Dip switch setting from stage 2 or 3 for both transmitter and receiver and check all wiring and
setting, then connect the monitor.
2. Please disconnect the receiver from the monitor if the picture is not normal, or when there is no picture
display. Then increase the stage of Dip switch at the receiver and re-connect again.
3. If still no picture display, try to increase the stage of Dip switch at the transmitter and re-connect again.
4. The picture may be distorted at the upper side when using a CRT monitor. If this happens, you could
increase the stage of Dip switch at the transmitter to improve picture quality.
5. Dip switch by accumulate setting. For Example:
3 + 2 + 1 = 6
3 + 2 = 5
3 + 1 = 4
3 = 3
6. Improper setting may cause no picture display.
7. After the setup, you could adjust the contrast and brightness of the monitor for the best picture quality.