6 - 16
• Yes
End
1
-1
• Take the measurement of the following voltage readings at connector CN2 on the power
supply/sensor board:
Voltage between Pins 1 and 3: ... about 40 V AC
Voltage between Pins 5 and 6: ... about 9.2 V AC
Are the voltages within the normal range?
• Yes Is fuse F3 on the power supply/sensor board blown?
• No
Replace the power supply/sensor board.
• Yes Replace fuse F3 (if it blows again, check the resistance of the registration and
main/drum motors. If it is faulty, replace motors or replace the power supply/
sensor board or main control board).
• No
Is the AC input voltage output between Pins 1 and 2 of connector CN1 on the
power supply/sensor board normal?
• Yes Replace the AC transformer.
• No
Is fuse F1 or F2 on the power supply/sensor board blown?
• No
Replace the power supply/sensor board.
• Yes
Replace blown fuse F1 or F2 (if is blows again, replace the power supply/sensor
board).
ACIN
Filter
Circuit
CN1
CN2
Power supply/sensor board
F1
L
N
FG
F2
1
2
F3
1, 2
3, 4
+30 V
Smoothing
Circuit
+5 V
Stabilizing
Circuit
+30 V
+5 V
0 V
CN3
6
±
8 Rectifying/
Smooting
Circuit
5
+8 V
-8 V
AC Transformer
Fuse Ratings
120 V
230 V
F3
AC Input
Fuse
17, 18
12
9, 15, 16
24
22
Thermal Fuse
F2
F1
125 V 3.15A
125 V 1.6 A
125 V 6.3 A
250 V 2.5A
–
250 V 5 A
Figure 6-1 Low-voltage Power Supply Block Diagram
Содержание OKIPAGE 12i Series
Страница 6: ...1 CONFIGURATION...
Страница 12: ...1 6 7 Flash memory SIMM...
Страница 17: ...2 OPERATION DESCRIPTION...
Страница 28: ...2 11 PRINT N OUT Sensor OFF PRDY N DM ON N RM ON INSNS OUTSNS N Feed stop IN Sensor OFF Feed start Figure 2 5...
Страница 48: ...3 PARTS REPLACEMENT...
Страница 52: ...3 4 Upper cover unit Figure 3 2 Upper cover...
Страница 80: ...4 ADJUSTMENT...
Страница 88: ...5 PERIODICAL MAINTENANCE...
Страница 92: ...6 TROUBLESHOOTING PROCEDURES...
Страница 125: ...6 33 Figure 6 5 Contact Power supply sensor board Contact plate for transfer roller...
Страница 126: ...7 WIRING DIAGRAM...
Страница 140: ...8 PARTS LIST...
Страница 144: ...8 4 Figure 8 2 Upper cover unit 1...
Страница 145: ...8 5 Table 8 2 Upper cover unit No Name Rating Part No Use Remarks ODA Part No Cover Upper 1 1 40715101...
Страница 146: ...8 6 Figure 8 3 Base unit 16 17 29 9 18 6 13 2 20 21 27 19 22 24 1 4 19 22 25 15 26 28 3 12 20 21 8 5 7 10 11 23...
Страница 168: ...E 1 Appendix E Multi Purpose Feeder Maintenance...
Страница 187: ...E 20 5 2 PCB Layout OLEV 11 PCB CN3 CN2 SEN2...
Страница 188: ...E 21 6 PARTS LIST Figure 6 1 Multi Purpose Feeder 9 5 7 6 4 1 2 3 8...
Страница 190: ...F 1 Appendix F High Capacity Second Paper Feeder Maintenance Manual...
Страница 206: ...F 17 5 2 PCB Layout TQSB 2 PCB CONTROLLER MOTOR DRIVER SEN2 SEN1 OSC PU MOTOR...
Страница 207: ...F 18 Figure 6 1 High Capacity Second Paper Feeder 1 2 4 3 5 6 PARTS LIST...
Страница 210: ...F 21 SECTION1 CABINET CASSETTE ASSEMBLY 5 6 3 25 2 4 7 8 1...
Страница 211: ...F 22 SECTION2 MECHANICAL ASSEMBLY 21 9 11 10 12 13 23 22 14 24 15 16 17 19 18 20 A A B B...
Страница 213: ...G 1 Appendix G Network Option Board Maintenance...
Страница 226: ...Oki Data Corporation 4 11 22 Shibaura Minato ku Tokyo 108 8551 Japan Tel 03 5445 6162 FAX 03 5445 6189...