![Oki ML420 Series Скачать руководство пользователя страница 65](http://html2.mh-extra.com/html/oki/ml420-series/ml420-series_maintenance-manual_3760493065.webp)
42113901TH01 Rev.3
65 /
Oki Data CONFIDENTIAL
3.3.9 Carriage Cable
(1)
Remove the printhead (see 3.3.1).
(2)
Remove the upper cover (see 3.3.4 (1) – (5)).
(3)
Remove the gear case Assy (see 3.3.5).
(4)
Remove the space motor (see 3.3.7).
(5)
Remove the space rack (3.3.8).
(6)
Remove two screws
1
, release the Control Board
2
and PCB sheet
9
by lifting clamp
8
, and disconnect cable from connector
3
,
4
,
5
,
6
.
(7)
Remove carriage cable
7
from fasteners on frame.
(8)
To install, follow the removal steps in the reverse order.
Note on installation:
(1) Take care not to fold the carriage cable
7
during installation. Curve slightly the
carriage cable
7
when assembling into the fasteners.
(2) Make sure that the paper end lever
A
will not contact the Paper end Sensor
0
when
mounting the Control Board.
(3) Make sure that there is not any dust or oil on the connector contact sections A to
D. If it is found, wipe it off by alcohol.
7
0
A
7
2
Claw
Claw
A
B
C
D
8
6
4
3
9
2
5
1
Содержание ML420 Series
Страница 1: ...Oki Data CONFIDENTIAL ML420 ML421 Maintenance Manual 080603F PRINTING SOLUTIONS...
Страница 117: ...42113901TH01 Rev 3 117 Oki Data CONFIDENTIAL Figure B 2 Printer General Assy 6 9 7 1 2 3 11 10 4 5 8...
Страница 122: ...42113901TH01 Rev 3 122 Oki Data CONFIDENTIAL Figure B 4 Carriage Assy 12 9 8 6 14 4 10 7 11 13 3 1...