www.okinternational.com
MFR Rev. 2/13/2006
7
A/C Power LED
•
Green---Power On
•
Red------Input Ground Fault
•
Off-------Power Off
Channel LED
•
Green--------------On / Ready
•
Flashing Green—Standby
•
Red-----------------Ground continuity
fault
and
no power
•
Off------------------Channel not
selected or auto off
. Auto Off – Hand-piece Power Off
•
Sequential to Standby Mode
•
Factory default setting 30 minutes.
•
Channel LED will be off.
•
The auto off time may be adjusted
from 0 minutes (deactivated) to 150
minutes at 10 minutes intervals.
Standby – Hand-piece Power Low
•
Factory default setting 30 minutes.
•
Channel LED will flash green.
•
The standby time may be adjusted
from 0 minutes (deactivated) to 75
minutes at 5 minutes intervals.
LED Indications and Meaning
Standby & Auto Off Mode
These Modes are designed to extend tip life.
Lifting the hand-piece or heavy vibration will trigger the motion detect switch and return full
power to the tip and re-start counter.
Use a 2.5 mm screwdriver to adjust on base of unit.
www.okinternational.com
MFR Rev. 2/13/2006
8
SmartHeat & Calibration
SmartHeat technology establishes and retains heater idle temperature by virtue of Curie effect
inside the heater core. This phenomenon occurs at the atomic level and consequently idle
temperature cannot shift over time nor can it be altered by the operator. Accordingly the
system requires absolutely no calibration. Contact us at [email protected]
Specifications
Ambient Operating Temperature
10- 40°C
Maximum Enclosure Temperature
55°C
Input Line Voltage
100- 240 VAC, grounded circuit
Input Line Frequency
50/60 Hz
Recommended Air Pressure Input
450kPa (65PSI) MFR-PS2X only
Power Consumption
75 Watts max. (MFR-PS2K), 70 Watts max. (MFR-
PS2X)
Output Power
50 Watts max. at 22°C ambient temperature
Output
Frequency
450
KHz
Power Cord 3-Wire
183cm (18/3”) SJT
Dimensions w x d x h
170mm (7”) x 200mm (8”) x 152.5mm (6”)
Certification / Marking
cTUVus, CE
Tip-to-Ground Potential
<2mV
Tip-to-Ground Resistance
<2 ohms
Idle Temperature Stability
± 1.1°C in still air
Desolder Hand-piece Cable Length
L=152cm (60”), burn proof, ESD safe
Other Hand-piece Cable Length
L=122cm (48”), burn proof, ESD safe
Hand-piece Connector
8-pin circular DIN
Workstand Dimensions w x d x h
100 mm (4”) x 200 mm (8”) x 100 mm (4”)
Warranty
Please visit OK International’s web page (
www.okinternational.com
) where you will find
available information on systems, accessories, technical notes, and more.
OK International warrants the MFR against any defects in materials or workmanship for one
(1) year from the date of purchase by the original owner. This Warranty excludes normal
maintenance and shall not apply to any opened, misused, abused, altered or damaged items.
If the product should become defective within the warranty period, OK International will repair
or replace it free of charge at its sole option. The repaired or replacement item will be shipped,
freight prepaid, to the original purchaser. The warranty period will start from the date of
purchase. If the date of purchase cannot be substantiated the date of manufacture will be
used as the start of the warranty period.
The MFR-HPS/-HDS handpiece uses a coil assembly which is a consumable item. OK
International warrants the coil assembly against material and workmanship defects for a
period of 30 days. For contact details for Warranty and Support look for your local office
details at:
www.okinternational.com
Содержание MFR-DSI