2
2-51 Using the EFI Spectrometer ES-1000
ES3640e MFP Color Guide - 51
4. In the Generate Measurement Page pane, click Print.
The Print Options dialog box appears.
5. Choose the appropriate options and click Print.
For Page Type, choose either 21 or
34 Sorted Patches, or 21 or 34
Randomized Patches. Sorted
patches are printed on the page in
the order of their hue and
saturation levels. Randomized
patches are printed on the page in
random order, to help compensate
for density inconsistencies on
different areas of the page.
Page Size is automatically set to
LTR/A4 for 21 patches, or 11x17/A3 for 34 patches.
Input Tray is automatically set to Auto Select.
6. Retrieve the printed measurement page from the printer.
7. In the Get Measurements pane,
click Measure.
The Measurement Options dialog
box appears.
Page Type is automatically set to
the type that you selected in
8. Check the settings, and
click Measure.
The Information dialog box
appears.
Содержание ES3640eMFP
Страница 1: ......