Oki ES1220n Скачать руководство пользователя страница 8

8

English

Appearance and Odor:

 Magenta powder, no odor.

Odor Threshold:

 Not available.

Percent Volatile:

 Not available.

Fire and Explosion Hazard Data __________

Minimal fire hazard. Large quantities may cause risk of dust 
explosion.

Flash Point (Method Used):

 Not applicable.

Flammable Limits

Lower Explosive Limit:

 Not available.

Upper Explosive Limit:

 Not available.

Auto-Ignition Temperature

: Not available.

Explosion Data

Sensitivity to Mechanical Impact:

 Not available.

Sensitivity to Static Discharge:

 Not available.

Extinguishing Media:

 In case of small fire, use CO

2

. In 

case of large fire, shut off air by spraying with water or 
foam.

Special Fire Fighting Procedures:

 Fight fire from upwind 

position. Avoid inhalation of smoke or gases. Wear self-
contained breathing apparatus.

Hazardous Combustion Products:

 Carbon monoxide, 

oxides of nitrogen.

Toxicological Properties _________________

Routes of Entry:

 Inhalation, Ingestion, Eyes, Skin.

Effects of Acute Exposure:

 Not available.

Effects of Chronic Exposure:

 Not available.

Exposure Limits:

 Not available.

Irritancy:

 Not available.

Sensitivity:

 Not available.

Carcinogenicity

IARC:

 Silica Dioxide—Group 3. Not classifiable.

NTP:

 No components are listed.

OSHA:

 No components are listed.

Reproductive Toxicity:

 Not available.

Teratogenicity:

 Not available.

Mutagenicity:

 Not available.

Name of Toxicoligically Synergistic Products:

 Not 

available.

Reactivity Data _________________________

Stability:

 Stable in general.

Conditions to Avoid: 

Avoid excess heat and all sources of 

ignition.

Polymerization:

 Will not occur.

Hazardous Decomposition or Byproducts:

 Combustion 

products include harmful gases such as carbon monoxide 
and nitrogen oxides.

Incompatibility:

 Not available.

Preventive Measures ____________________

Personal Protective Equipment

Respiratory Protection:

 Not normally required. For large 

spills, use dust respirator during cleanup.

Protective Gloves and/or Eye Protection:

 Not normally 

required. For large spills, use rubber gloves and safety 
goggles during cleanup.

Engineering Controls

Ventilation:

 Outside of normal ventilation, not normally 

required.

Other Protective Equipment and/or Hygienic Practices:

 

None.

Spill Cleanup

Small Spills

1. Remove sources of ignition.

2. Carefully clean up the spill with a wet cloth, avoiding 

inhalation of fine dust.

Large Spills

1. Remove sources of ignition and keep unnecessary and 

unprotected personnel away from area.

2. Wear protective gear: respirator, rubber gloves, safety 

goggles.

3. Vacuum the spill, then wipe up remainder with a wet 

cloth.

Waste Disposal

• Prevent release of material into natural waters and sewers.

• Follow appropriate federal, state and local regulations.

• Small amounts can be incinerated.

Careful! Combustion can create harmful gases such as 
carbon monoxide and nitrogen oxides.

• Large amounts must be passed to a licensed waste 

contractor.

Precautions

Precautions for Handling or Storage: 

Protect from the 

sun. Store in a cool room, under 104°F (40°C). Keep out of 
reach of children.

Other Precautions:

 None.

Shipping Information

Special Shipping Information:

 Non hazardous. Handle 

container carefully to avoid shock. Do not drop. Keep dry.

Preparation Date of MSDS_______________

Date:

 September 4, 2003.

Prepared by:

Oki Data Americas, Inc
Engineering Services Department.
2000 Bishops Gate Blvd.
Mt. Laurel, NJ 08054-4620

Tel: (856) 235-2600
Fax: (856) 222-5320

my.okidata.com

Содержание ES1220n

Страница 1: ...rous conditions must be removed from the site prior to and throughout the time a service technician is present The service technician may refrain from entering the premises or continuing to provide se...

Страница 2: ...te assistance with Basic operating procedures Sales and service referrals Parts and consumable referrals Product information Customer Support Professionals 1 800 654 3282 1 800 OKI DATA Customer Suppo...

Страница 3: ...dels This Oki Data apparatus complies with the Class B limits for radio interference as specified in the IC Radio Interference Regulations European Union Council of the European Communities EUCEC EUCE...

Страница 4: ...printer has been exposed to water The printer has been dropped or the cabinet is damaged The printer does not function normally when you are following the operating instructions Material Safety Data S...

Страница 5: ...ctivity Data _________________________ Stability Stable in general Conditions to Avoid Avoid excess heat and all sources of ignition Polymerization Will not occur Hazardous Decomposition or Byproducts...

Страница 6: ...fficient of water oil Distribution Not available Appearance and Odor Cyan powder no odor Odor Threshold Not available Percent Volatile Not available Fire and Explosion Hazard Data__________ Minimal fi...

Страница 7: ...ta Sheet MSDS 58357506 for Magenta Toner P N 52115103 Contact Information ____________________ For more information contact Oki Data at 2000 Bishops Gate Boulevard Mount Laurel NJ 08054 4620 Emergency...

Страница 8: ...cts Combustion products include harmful gases such as carbon monoxide and nitrogen oxides Incompatibility Not available Preventive Measures ____________________ Personal Protective Equipment Respirato...

Страница 9: ...fficient of water oil Distribution Not available Appearance and Odor Black powder no odor Odor Threshold Not available Percent Volatile Not available Fire and Explosion Hazard Data__________ Minimal f...

Страница 10: ...a wet cloth Waste Disposal Prevent release of material into natural waters and sewers Follow appropriate federal state and local regulations Small amounts can be incinerated Careful Combustion can cr...

Страница 11: ...nt toute la dur e de l intervention de ce dernier Toute condition dangereuse doit tre supprim e des installations avant l arriv e du technicien et pendant toute la p riode o le technicien est pr sent...

Страница 12: ...taill e et mise jour des centres de service apr s vente agr s d Oki Data tats Unis acc dez www okidata com et cliquez sur Dealer Locator tats Unis et Canada composez le 1 800 654 3282 1 800 OKI DATA P...

Страница 13: ...fe de l imprimante Ne la placez pas sur une surface souple comme une couverture un divan ou un coussin Les a rateurs pourraient tre obstru s et provoquer une surchauffe de l imprimante Prot gez l impr...

Страница 14: ...ne environ 4 en poids N de CAS Confidentiel PEL OSHA Non tabli TLV ACGIH Non tabli LD50 Non disponible LC50 Non disponible Silice environ 2 en poids N de CAS Confidentiel PEL OSHA Non tabli TLV ACGIH...

Страница 15: ...hets Emp chez le d versement du mat riau dans les eaux naturelles et les gouts Observez les r glementations locales en vigueur Les petites quantit s peuvent tre incin r es Attention Les produits de co...

Страница 16: ...es d absorption Inhalation ingestion yeux peau Effets d une exposition aigu Non disponible Effets d une exposition chronique Non disponible Limites d exposition Non disponible Propri t irritante Non d...

Страница 17: ...Toner sur la peau Nettoyez avec beaucoup d eau froide et du savon Au besoin consultez un m decin Note De petites quantit s de toner renvers es sur la peau ou les v tements s liminent facilement l aide...

Страница 18: ...gnez de l endroit le personnel inutile et non prot g 2 Utilisez un quipement protecteur respirateur gants de caoutchouc lunettes protectrices 3 Ramassez le d versement avec un aspirateur puis essuyez...

Страница 19: ...u en vaporisant de l eau ou de la mousse Proc dures sp ciales en cas d incendie Combattez l incendie contre le vent vitez d inhaler la fum e ou les gaz Utilisez un appareil respiratoire autonome Produ...

Страница 20: ...iales sur l exp dition Informations sp ciales sur l exp dition Inoffensif Manipulez le contenant avec soin pour viter les chocs Ne laissez pas tomber Gardez au sec Date de r daction de la fiche techni...

Отзывы: