OK International DX-200 Скачать руководство пользователя страница 4

 

 
8

 

TROUBLESHOOTING 

 
PROBLEM POSSIBLE 

CAUSE 

CORRECTION 

LCD does not 
light 

 

No power input 

 
 

 

Check power cord 
connections 

 

Turn on power 

 

System will not 
actuate 

 

Foot switch not 
plugged in or 
improperly 
plugged in 

 

Defective foot 
switch 

 

 

Broken wire or 
loose connection 
inside unit 

 

 

Defective 
solenoid 

 

Defective PC 
board 

 

 

Check foot switch 
connection 

 

 

Foot switch needs 
to be repaired or 
replaced 

 

Unplug power cord 
and disconnect air 
supply.  Remove 
cover and check 
for broken wires or 
loose connections 

 

 

Replace solenoid 

 

Replace PC board 

 

System will not 
pressurize 

 

Insufficient air 
pressure 

 

Air hoses not 
plugged in 

 

Regulator 
defective 

 

Increase air supply 
pressure 

 

Check connection 

 

Replace regulator 

System will not 
pull vacuum 

 

Vacuum setting is 
too low 

 

Defective 
solenoid 

 

Defective 
vacuum venturi 

 

Defective 
vacuum needle 
valve 

 

 

Increase vacuum 
setting 

 

Replace solenoid 
valve 

 

Replace venturi 

 

Replace needle 
valve 

Inconsistent 
dispensing 

 

Air bubbles in 
Adhesives 

 

Dispense time is 
too low 

 

Dispense needle 
started to clog 

 

Reduce vacuum 
setting 

 

Increase 
dispensing time 

 

Replace needle 

 

 

8

 

9

 

MAINTENANCE  

 

The dispenser is designed and built to be relatively maintenance free.  To assure 
trouble free operation, the following recommendations should be followed: 

1.

 

Make certain air supply is clean and dry. 

2.

 

Avoid turning barrels upside down or laying barrel so that material may 
run through air line to internal components. 

3.

 

Avoid connecting the unit to excessive moisture or solvent saturation. 

4.

 

Avoid connecting air supply exceeding 100 psi (6.9 bars)  

5.

 

Use only Amyl Alcohol to clean outside surface of the main housing. 

6.

 

Use only soft cloth to clean the LCD. 

 

10

 

SPARE PARTS  AND ACCESSORIES 

 

For DX-3xx/2xx spare parts and accessories information, please visit the DX-
3xx/2xx User Guide webpage at 

http://www.okinternational.com

 

 

 

 

 

11

 

LIMITED WARRANTY 

 
OK International warrants this product to the original purchaser for a period of one 
(1) year from date of purchase to be free from material and workmanship defects but 
not normal wear-and-tear, abuse and faulty installation.  Defective product or 
subassembly and components under warranty will be repaired or replaced (at OK 
International's option) free of charge. Customer with defective product under 
warranty must contact the nearest OK International office or distributor to secure a 
return authorization prior to shipping the product to the assigned OK International 
authorized service center.  For nearest OK International office or distributor contact 
information, please visit www.okinternational.com.   OK  International reserves the 
right to make engineering product changes without notice. 
 

12

 

I/O Configuration and End of Cycle Switch 

 

For DX-3xx/2xx I/O Configuration and End of Cycle Switch information, please 
visit the DX-3xx/2xx User Guide webpage at 

http://www.okinternational.com 

Содержание DX-200

Страница 1: ...resulting from unintended applications of its equipment Unintended uses may result form taking the following actions Making changes to equipment that has not been recommended in the User Guide Using i...

Страница 2: ...Indoor Use Altitude up to 2 000m 6 562ft Operating Temperature 0 C to 50 C 32 F to 122 F Storage Temperature 10 C to 60 C 14 F to 140 F Max Relative Humidity 80 for temperature up to 31 C 87 8 F Decre...

Страница 3: ...move the cursor to the next position 4 Press the and button to set the time 5 Press and hold the Set button 3 for two seconds to save the data Items Description 1 To Air Source 2 Air Filter Not Inclu...

Страница 4: ...ls upside down or laying barrel so that material may run through air line to internal components 3 Avoid connecting the unit to excessive moisture or solvent saturation 4 Avoid connecting air supply e...

Страница 5: ...2 1 2 3 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 10 11 10 12 I O 10 1 1 1 OK International 3 1 2 PSA15R 240P ZJ PW118RA2403B01 PW118RA2403H01 PW118RA2403M01 PW118RA2403G01 881 000 000 881 000 000 2...

Страница 6: ...7 0 1 2 kg 2 6lbs 24VDC 10W 100 psi 6 9 II I 2000m 6562ft 0 C 50 C 32 F 122 F 10 C 60 C 10 00 C 60 00 C 31 C 87 8 F 80 40 C 104 F 50 0 100 psi 0 6 9 406mm 16 0 020 99 999 0 001 600 LCD 16 X 2 5 4 1 0...

Страница 7: ...6 B DX 300 A 1 2 3 4 5 5 TSD800 6 1 2 3 4 5 6 7 8 9 10 11 12 I O 13 14 15 16 7 1 2 3 4 2 0...

Страница 8: ...8 6 1 0 6 1 1 1 2 2 MANUAL MODE 3 6 5 4 5 7 6 8 7 6 2 1 2 TIMED MODE 2 3 2 3 3 4 5 3 2 6 6 3 65 535 LCD 3 2 3 4 9 7...

Страница 9: ...2 250 2 2 251 2 2 250 2 2 251 Save and Exit 2 2 251 TIME SETTING COUNTER RESET Press then release Press and hold for approximately 2 seconds then release POWER MODE SET Time setting Press and hold for...

Страница 10: ...6 LCD 10 DX 3xx 2xx http www okinternational com DX 3xx 2xx 11 OK International OK International OK International OK International OK International www okinternational com OK International 12 I O DX 3...

Страница 11: ...2 1 2 3 2 3 3 4 4 5 5 6 6 6 7 7 8 8 9 9 10 10 10 11 10 12 I O 10 1 1 1 OK International 3 1 2 PSA15R 240P ZJ PW118RA2403B01 PW118RA2403H01 PW118RA2403M01 PW118RA2403G01 881 000 000 881 000 000 2...

Страница 12: ...W 100 psi 6 9 bars II I 2 000m 6 562ft 0 C 50 C 32 F 122 F 10 C 60 C 14 F 140 F 31 C 87 8 F 80 40 C 104 F 50 0 100 psi 0 6 9 bars 406mm 16 Hg 0 020 99 999 0 001 600 LCD 16 X 2 5 4 1 2 3 4 5 6 7 8 9 10...

Страница 13: ...6 B DX 300 A 1 2 3 4 5 5 TSD800 6 6 1 0 6 1 1 1 2 2 MANUAL MODE 3 6 5 4 5 7 6 8 7 1 2 3 4 2 0 7 6 2 1 2 TIMED MODE 2 3 3 3 4 5 3 6 6 3 65 535 LCD 3 3...

Страница 14: ...2 250 2 2 250 2 2 251 2 2 250 2 2 251 Save and Exit 2 2 251 TIME SETTING COUNTER RESET Press then release Press and hold for approximately 2 seconds then release POWER MODE SET Time setting Press and...

Страница 15: ...ttp www okinternational com 11 OK International 1 OK International OK International OK International OK International www okinternational com OK International 12 I O DX 3xx 2xx I O DX 3xx 2xx http www...

Страница 16: ...403G01 881 000 000 881 000 000 2 On Off 4 3 152mm X 165mm X 178mm 6 X 6 5 X 7 0 1 2 kg 2 6lbs 24VDC 10W 100 psi 6 9 bar II I 2 000m 6 562ft 0 C 50 C 32 F 122 F 10 C 60 C 14 F 140 F 31 C 80 87 8 F 40 C...

Страница 17: ...5 4 1 0 8 1 3 2 5 4 15 16 10 12 14 11 9 6 7 6 B DX 300 A 1 2 3 4 5 A 5 TSD800 6 1 2 3 4 5 6 7 8 9 10 11 12 I O 13 14 15 16 2 0...

Страница 18: ...7 6 1 0 6 1 1 1 2 2 3 5 6 4 5 7 6 9 8 7 6 2 1 2 2 3 2 3 3 4 5 2 6 1 2 3 4 8 6 3 65 535 LCD 3 2 3 4 7...

Страница 19: ...2 251 2 2 250 2 2 251 Save and Exit 2 2 251 TIME SETTING COUNTER RESET Press then release Press and hold for approximately 2 seconds then release POWER MODE SET Time setting Press and hold for approxi...

Страница 20: ...15psi 1 03 bar 5 6 LCD 10 DX 3xx 2xx DX 3xx 2xx http www okinternational com 11 OK International 1 12 OK International OK International OK International OK International www okinternational com OK In...

Отзывы: