background image

                                     

••••  www.ojedausa.com  •  [email protected]  •  Pg. 9  ••••

    

Part Number 100330051

 

MAINTENANCE GUIDELINES 

 

 

Regularly and carefully cleaning the equipment prevents deterioration and product alteration.

 

  

CLEANING THE UNIT

 

  
Clean  every  week  with  only  a  damp  piece  of  cloth  and  neutral  soap  each 
external and internal surface, and dry them with a clean soft cloth

 

 

Never use flammable or abrasive products. The unit must never 

be cleaned 

with water jets. 
 
IMPORTANT:

  During  maintenance  and  cleaning  operations,  make  sure 

that  good  visibility  conditions  exist  in  the  working  area,  using  other  light 
sources  in  case  it  is  needed.  Be  very  careful  when  working  with  moving 
and/or high-temperature parts. 

 

 

CLEANING THE CONDENSER COIL 

 

IMPORTANT WARRANTY INFORMATION: 

Condensers accumulate dirt and require regular cleaning.  Dirty condensers result in 

compressor failure, product loss, and lost sales; which are not covered by warranty 

 
If you keep the condenser(s) clean you will minimize your service expense and lower your electrical 
costs.  The following is a step-by-step guideline for the cleaning of the condenser(s): 
 

1.

 

Disconnect power to the unit. 

2.

 

Take off front lower grill assembly by removing the two (2) screws in the top corners. 

3.

 

Clean off accumulated dirt from the condenser coil(s) using a vacuum and/or a damp rag. 

4.

 

Replace the grill assembly. 

5.

 

Connect power to the unit and verify that when required the condensing unit(s) are running. 

 
If you cannot remove the dirt adequately, please call your refrigeration service company. 
 

Содержание RVP10SL

Страница 1: ...SC 29306 864 574 6004 Fax 864 574 6005 Part Number 100330051 www ojedausa com INSTALLATION AND OPERATION MANUAL RVP10SL RVP12SL RVP10 RVP12 RVP27 RV2P40 RV2P49 RV3P72 Congratulations You have just pu...

Страница 2: ...terials available Your Ojeda cooler when installed correctly and properly maintained will give you many years of trouble free operation WARNING USE THIS APPLIANCE FOR ITS INTENDED PURPOSE AS DESCRIBED...

Страница 3: ...E EQUIPMENT If the equipment will be kept in storage it is suggested to keep it in its original packing In case you need your equipment to be inactive for a long period of time after being used verify...

Страница 4: ...orrect performance of the refrigerating system it is very important to leave at least 10 cm 4 of free space both at the sides and back to allow proper air circulation The location of the cooler must b...

Страница 5: ...3P72 120 9 5 15 Before connecting your equipment check that the electrical data on the data plate match your electrical output IMPORTANT NOTICE PLUG THE EQUIPMENT INDEPENDENTLY TO A LOAD CENTER WITH A...

Страница 6: ...ion of the unit based on the temperature of the air discharging from the evaporator at the back of the unit In order to achieve the desired product temperature the electronic control is factory adjust...

Страница 7: ...be thawed by emptying the cabinet of product and removing power until the coil is clear CONDENSATION EVAPORATOR TRAY When the equipment operates condensed water from the environment is collected on t...

Страница 8: ...limb on top of the unit Never use direct or indirect water jets on the unit Do not allow the electronic control to be adjusted by customers or unqualified personnel For any adjustment you must contact...

Страница 9: ...gh temperature parts CLEANING THE CONDENSER COIL IMPORTANT WARRANTY INFORMATION Condensers accumulate dirt and require regular cleaning Dirty condensers result in compressor failure product loss and l...

Страница 10: ...early indicating the equipment model and serial number If replacing parts is required do it through your distributor WARNING Always ask for original spare parts AUTHORIZED DISTRIBUTOR ________________...

Отзывы: