background image

PREVENTION

Part Number 100330051

www.ojedausa.com | 6

Do not block the lower ventilation grille with the packages about to be loaded.  

Do not over hang the shelf.

Do not press the product against the rear wall

Never exceed the shelf weight limits. 

ELECTRONIC TEMPERATURE CONTROL

The unit is provided with an electronic temperature control that controls the operation of the unit 
based on the temperature of the air entering the evaporator at the front of the unit. 
In order to achieve the desired product temperature, the electronic control is factory adjusted to turn 
off the refrigeration system at 35ºF and start it at 39.5ºF. 
When you plug the unit in, the control display will illuminate. However, there is a start-up delay of 2 
minutes before the compressor(s) are energized. This delay avoids the possibility that during a pow-
er failure the compressors are forced to restart before the refrigerant pressures are equalized. 
The control has been factory-adjusted with a defrosting cycle scheduled to last 6 minutes every hour 
to ensure that the evaporator performs without any ice build-up. 
None of the factory-programmed electronic control parameters can be modified unless an access 
code is entered (only your distributor’s technical personnel have that code).  

UNIT OPERATIONS AND COMPONENTS

Содержание RHM Series

Страница 1: ...ations You have just purchased the finest commercial refrigeration available RMH 40 Part Number 100330051 www ojedausa com RMH SERIES 460 Southport Commerce Blvd Spartanburg SC 29306 Phone 864 574 600...

Страница 2: ...u many years of trouble free operation WARNING USE THIS APPLIANCE FOR ITS INTENDED PURPOSE AS DESCRIBED IN THIS MANUAL When using electrical appliances basic safety precautions should be followed incl...

Страница 3: ...oap and carefully drying it cover it with a polyethylene film or similar waterproof material The following procedure is recommended for uncrating the unit Remove the outer package by carefully cutting...

Страница 4: ...refrigerating system it is very important to leave at least 10 cm 4 of free space both at the sides and back to allow proper air circulation The location of the cooler must be kept away from sources o...

Страница 5: ...shelf brackets in the pilaster notches making sure they are at the same level such that the shelves remain horizontal IMPORTANT The products on each shelf must leave three to five centimeters of free...

Страница 6: ...ory adjusted to turn off the refrigeration system at 35 F and start it at 39 5 F When you plug the unit in the control display will illuminate However there is a start up delay of 2 minutes before the...

Страница 7: ...the evaporator is frozen it can be thawed by emptying the cabinet of product and removing power until the coil is clear The condensing unit can be pulled out sliding it approximately 40 cm 16 to allow...

Страница 8: ...For any adjustment you must contact your distributor Verify that the hot air stream from the condenser towards the back of the unit is not directed to other refrigeration units which would compromise...

Страница 9: ...ing Dirty condensers result in compressor failure product loss and lost sales which are not covered by warranty If you keep the condenser s clean you will minimize your service expense and lower your...

Страница 10: ...ating the equipment model and serial number If replacing parts is required do it through your distributor WARNING Always ask for original spare parts AUTHORIZED DISTRIBUTOR ___________________________...

Отзывы: