background image

INSTALLATION AND 

OPERATION MANUAL

Congratulations! You have just 

purchased the finest commercial 

refrigeration available.

RMH 40

Part Number 100330051

www.ojedausa.com

RMH SERIES

460 Southport Commerce Blvd. 

Spartanburg SC 29306

Phone: 864-574-6004 

Fax: 864-574-6005

RMH-8

RMH-33PT

RMH-10SL

Содержание RHM Series

Страница 1: ...ations You have just purchased the finest commercial refrigeration available RMH 40 Part Number 100330051 www ojedausa com RMH SERIES 460 Southport Commerce Blvd Spartanburg SC 29306 Phone 864 574 600...

Страница 2: ...u many years of trouble free operation WARNING USE THIS APPLIANCE FOR ITS INTENDED PURPOSE AS DESCRIBED IN THIS MANUAL When using electrical appliances basic safety precautions should be followed incl...

Страница 3: ...oap and carefully drying it cover it with a polyethylene film or similar waterproof material The following procedure is recommended for uncrating the unit Remove the outer package by carefully cutting...

Страница 4: ...refrigerating system it is very important to leave at least 10 cm 4 of free space both at the sides and back to allow proper air circulation The location of the cooler must be kept away from sources o...

Страница 5: ...shelf brackets in the pilaster notches making sure they are at the same level such that the shelves remain horizontal IMPORTANT The products on each shelf must leave three to five centimeters of free...

Страница 6: ...ory adjusted to turn off the refrigeration system at 35 F and start it at 39 5 F When you plug the unit in the control display will illuminate However there is a start up delay of 2 minutes before the...

Страница 7: ...the evaporator is frozen it can be thawed by emptying the cabinet of product and removing power until the coil is clear The condensing unit can be pulled out sliding it approximately 40 cm 16 to allow...

Страница 8: ...For any adjustment you must contact your distributor Verify that the hot air stream from the condenser towards the back of the unit is not directed to other refrigeration units which would compromise...

Страница 9: ...ing Dirty condensers result in compressor failure product loss and lost sales which are not covered by warranty If you keep the condenser s clean you will minimize your service expense and lower your...

Страница 10: ...ating the equipment model and serial number If replacing parts is required do it through your distributor WARNING Always ask for original spare parts AUTHORIZED DISTRIBUTOR ___________________________...

Отзывы: