Ojeda FMH Series Скачать руководство пользователя страница 4

Part Number 100330109

www.ojedausa.com | 4

PLACING AND INSTALLING EQUIPMENT

ENVIRONMENTAL CONDITIONS  

THIS UNIT CANNOT BE INSTALLED IN ENVIRONMENTS WITH EXPLOSIVE GASES. THE 

EQUIPMENT IS DESIGNED ONLY FOR INDOOR OPERATION.  

The unit must be located in an indoor environment where the ambient is maintained less than 
75/50%RH.
For the correct performance of the refrigerating system, it is very 
important to leave at least 10 cm (4”) of free space both at the 
sides and back to allow proper air circulation. 

The location of the cooler must be kept away from sources of 
heat and humidity including direct sunlight, toasters, ovens, 
coffee warmers, other appliances condenser air discharge, 
infrared heaters, or other heat generating appliances.  Keep the 
unit away from external doors.

The unit should be leveled prior to operation.

The unit must have casters, 6” legs, or sealed to the floor per NSF guidelines.

6” Adjustable Legs 

Casters 

Содержание FMH Series

Страница 1: ...ratulations You have just purchased the finest commercial refrigeration available FMH 12 Part Number 100330109 www ojedausa com FMH SERIES 460 Southport Commerce Blvd Spartanburg SC 29306 Phone 864 57...

Страница 2: ...u many years of trouble free operation WARNING USE THIS APPLIANCE FOR ITS INTENDED PURPOSE AS DESCRIBED IN THIS MANUAL When using electrical appliances basic safety precautions should be followed incl...

Страница 3: ...oap and carefully drying it cover it with a polyethylene film or similar waterproof material The following procedure is recommended for uncrating the unit Remove the outer package by carefully cutting...

Страница 4: ...efrigerating system it is very important to leave at least 10 cm 4 of free space both at the sides and back to allow proper air circulation The location of the cooler must be kept away from sources of...

Страница 5: ...revent their loss during transportation Insert the shelf brackets in the pilaster notches making sure they are at the same level such that the shelves remain horizontal IMPORTANT The products on each...

Страница 6: ...adjusted to turn off the refrigeration system at 10 F and start it at 0 F When you plug the unit in the control display will illuminate However there is a start up delay of 2 minutes before the compre...

Страница 7: ...0 cm 16 to allow servicing the condenser motor s compressor s and electrical components In order to service the condensing unit remove the two screws that hold the lower front grill one at each side R...

Страница 8: ...For any adjustment you must contact your distributor Verify that the hot air stream from the condenser towards the back of the unit is not directed to other refrigeration units which would compromise...

Страница 9: ...ing Dirty condensers result in compressor failure product loss and lost sales which are not covered by warranty If you keep the condenser s clean you will minimize your service expense and lower your...

Страница 10: ...ating the equipment model and serial number If replacing parts is required do it through your distributor WARNING Always ask for original spare parts AUTHORIZED DISTRIBUTOR ___________________________...

Отзывы: