background image

MAINTENANCE GUIDELINES CONT’D

Part Number 100330038

www.ojedausa.com | 9

Never use flammable or abrasive products. The unit must never be cleaned with water jets. 
IMPORTANT: During maintenance and cleaning operations, make sure that good visibility conditions 
exist in the working area, using other light sources in case it is needed. Be very careful when 
working with moving and/or high-temperature parts. 

CLEANING THE CONDENSER COIL 

IMPORTANT WARRANTY INFORMATION:  
Condensers accumulate dirt and require regular cleaning.  Dirty condensers result in compressor 
failure, product loss, and lost sales; which are not covered by warranty 
If you keep the condenser(s) clean you will minimize your service expense and lower your electrical 
costs.  The following is a step-by-step guideline for the cleaning of the condenser(s):

1. 

Disconnect power to the unit.

2. 

Take off front lower grill assembly by removing the two (2) screws in the top corners.

3. 

Clean off accumulated dirt from the condenser coil(s) using a vacuum and/or a damp rag.

4. 

Replace the grill assembly.

5. 

Connect power to the unit and verify that when required the condensing unit(s) are running.

If you cannot remove the dirt adequately, please call your refrigeration service company.

Содержание ALPA Series

Страница 1: ...tions You have just purchased the finest commercial refrigeration available ALPA 36 ALPA 77 ALPA 99 ALPA 120 Part Number 100330038 www ojedausa com ALPA SERIES 460 Southport Commerce Blvd Spartanburg...

Страница 2: ...maintained will give you many years of trouble free operation WARNING USE THIS APPLIANCE FOR ITS INTENDED PURPOSE AS DESCRIBED IN THIS MANUAL When using electrical appliances basic safety precautions...

Страница 3: ...soap and carefully drying it cover it with a polyethylene film or similar waterproof material The following procedure is recommended for uncrating the unit Remove the outer package by carefully cuttin...

Страница 4: ...as air conditioner supply or return grilles vent hoods appliance condenser air intake and discharge outside doors fans or other air movement devices Fig 2 The following horizontal distance should be c...

Страница 5: ...n fixed to the inside floor of the unit to prevent their loss during transportation Insert the shelf brackets in the pilaster notches making sure they are at the same level such that the shelves remai...

Страница 6: ...achieve the desired product temperature the electronic control is factory adjusted to turn off the refrigeration system at 35 F and start it at 39 5 F When you plug the unit in the control display wil...

Страница 7: ...of the unit In the event the evaporator is frozen it can be thawed by emptying the cabinet of product and removing power until the coil is clear The condensing unit can be pulled out sliding it appro...

Страница 8: ...act your distributor Verify that the hot air stream from the condenser towards the back of the unit is not directed to other refrigeration units which would compromise their operation Under no circums...

Страница 9: ...ing Dirty condensers result in compressor failure product loss and lost sales which are not covered by warranty If you keep the condenser s clean you will minimize your service expense and lower your...

Страница 10: ...nance item and will not be covered under warranty The drain lines can also be accessed by removing the bottom panel from the inside of the unit Fig 7 Both holes for the drain lines can be located Fig...

Страница 11: ...epairing and replacing at Ojeda USA s option any component with a similar component when upon our examination and to our satisfaction it is determined to be defective This warranty only applies to Oje...

Страница 12: ...ating the equipment model and serial number If replacing parts is required do it through your distributor WARNING Always ask for original spare parts AUTHORIZED DISTRIBUTOR ___________________________...

Отзывы: