© 2021 OJ Electronics A/S

HOLDING:

Addr-0 (REG-1) 

ExternCalibrate

Calibration Status 

(1 = Zero calibration) 

Addr-2 (REG-3) 

DisplayFlash

Flashing display 

(1 = Flashing)

INPUT:

Addr-0  (REG-1)  SoftwareVer   Software  Version 

1/100 

Addr-1 (REG-2)  Pressure 

Sensor pres- 

 

 

sure in Pa

Addr-3 (REG-4)  Flow 

 Air throughput.

 

 

 k-factor must be 

specified

Addr-4 (REG-5)  PressHiRes   Sensor pressure 

in 0.1 Pa

Addr-5  (REG-6)  PressAvrDyn   Dynamic 

averaging of 

PressHiRes

Addr-6 (REG-7)  PressAvrAbs   Dynamic av-

eraging of last 

30 PressHiRes 

measurements

SERVICE AND MAINTENANCE

PTH-6201-DF contains no components which 

require service or maintenance. 

Please contact your supplier if faults arise.

DISPOSAL AND ENVIRONMENTAL 

PROTECTION

Help protect the environment by disposing of 

the packaging and redundant products in a 

responsible manner.

Product disposal

Products marked with this symbol 

must not be disposed of along with 

household refuse but must be 

delivered to a waste collection centre 

in accordance with current localregula-

tions.

ALLGEMEINES

PTH-6201-DF ist ein über Modbus kommunizie-

render elektronischer Druckmessumformer, der 

insbesondere für die Differenzdruckmessung 

in Lüftungsanlagen geeignet ist. Der Druck-

messumformer kommt in Zusammenhang mit 

der Überwachung, Kontrolle und Regelung 

über einen elektronischen Regler, z. B. in einer 

SPS-, GLT- oder SCADA-Anlage, zum Einsatz. 

Alle Kommandos und Daten zwischen PTH-

6201-DF und der Regeleinheit werden digital 

per Modbus-Protokoll gesandt. Mit integrierter 

Modbus-Kommunikation ist PTH-6201-DF dank 

reduzierter Installationskosten besonders für die 

Integration in SPS-, GLT- und SCADA-Systemen 

geeignet.

Typische Anwendungsbereiche sind:

-   Messung des Drucks an einer gegebenen 

Stelle in einer Lüftungsanlage.

-   Differenzdruckmessung über einem Lüftungs-

filter, zur Ermittlung des optimalen Zeitpunkts 

für den Filteraustausch.

-   Differenzdruckmessung über einem Gebläse 

zur Regelung des Kanaldrucks.

FUNKTION

PTH-6201-DF ist ein Druckmessumformer für 

die Komfort- oder Prozessbelüftung, der über 

Modbus mit einer angeschlossenen Reglerein-

heit kommuniziert (siehe Abb. 4), und abhängig 

vom eingestellten Messbereich mittels Modus-

Kommunikation einen mit dem gemessenen 

Druck proportionalen Wert an die angeschlos-

sene Reglereinheit übermittelt. PTH-6201-DF 

ist mit einem Halbleiter-Druckmesselement 

ohne Luftdurchsatz ausgestattet, und daher 

vor Staub von der Lüftungsanlage geschützt. 

Das Druckelement ist temperaturkompensiert, 

sodass im gesamten spezifizierten Tempera-

turbereich eine optimale Druckmessung erzielt 

wird. (Siehe „Technische Daten“).

INSTALLATION

Das Gehäuse lässt sich ohne Werkzeug öffnen, 

durch Druck auf den Schnappverschluss, der 

sich seitlich der Stutzen befindet.

PTH-6201-DF ist mit 2 Schrauben auf ebener 

und fester Unterlage zu befestigen, und kann in 

beliebiger Position, ohne die Messgenauigkeit 

zu beeinträchtigen, montiert werden. PTH-

6201-DF wirkt auch wenn nur ein Schlauch auf 

den Stutzen (+ oder −) montiert ist, aber mit 

Rücksicht auf die Schutzart, sind auf beiden 

Schlauchstutzen, wenn nicht nach unten ger-

ichtet, Schläuche vorzusehen. 

Die Druckmessung erfolgt über Schläuche, 

wobei der höhere Druck am „+ Stutzen“ und der 

niedrigere Druck am „− Stutzen“ anzuschließen 

ist (siehe Abb. 3). 

Druckschläuche sind so kurz wie möglich zu 

halten und so zu befestigen, dass Schwingun-

gen vermieden werden. 

Mit Rücksicht auf eine optimale Druckmessung 

ist die Messung dort vorzunehmen, wo die ger-

ingste Gefahr turbulenter Strömung vorhanden 

ist, das heißt mitten im Lüftungskanal und mit 

einem Abstand von mindestens dem zwei-

fachen Kanaldurchmesser von Biegungen und 

dem sechsfachen von Abzweigen (siehe Abb. 

2).

Besteht die Gefahr von Kondenswasserbildung 

in den Anschlussschläuchen, ist PTH-6201-

DF so anzubringen, dass die kondensierende 

Flüssigkeit nicht in den Druckmessumformer 

zurückfließen kann.

Das Gehäuse verfügt über Befestigungslöcher, 

siehe Abb. 1.

Installation des Modbus-Kabels

Das Gehäuse lässt sich ohne Werkzeug öffnen, 

durch Druck auf den Schnappverschluss, der 

sich seitlich der Stutzen befindet. 

Der Modbus wird am PTH-6201-DF über vier 

Schraubklemmen angeschlossen, die zum 

Anschluss und zur Verschleifung des Modbus 

mit weiteren Modbus-Komponenten in der 

Disclaimer

OJ cannot be held liable for any errors in cata-

logues, brochures or other printed material. OJ 

reserves the right to alter its products without 

notice. This also applies to products already 

on order, provided that such alterations can be 

made without requiring subsequent changes in 

specifications already agreed. All trademarks in 

this material are the property of the respective 

companies. OJ and the OJ logotype are trade-

marks of OJ Electronics A/S. All rights reserved.

OJ ELECTRONICS A/S

Stenager 13B · DK-6400 Sønderborg

Tel. +45 73 12 13 14 · Fax +45 73 12 13 13

[email protected] · www.ojelectronics.com

CE MARKING

OJ Electronics A/S hereby declares that the 

product is manufactured in accordance with 

Council Directive 92/31/EEC on electromagnetic 

compatibility (and subsequent amendments) 

and Council Directive 73/23/EEC on electrical 

equipment designed for use within certain volt-

age limits (and subsequent amendments).

Applied standards

EMC emission  

EN 61000-6-3

EMC immunity 

EN 61000-6-2

Deutsch

ABBILDUNGEN

Folgende Abbildungen finden sich ganz hinten 

in der Anleitung:

Abb. 1:   Maßskizze

Abb. 2:    Platzierung des Messumformers i. V. 

m. Biegungen und Abzweigen

Abb. 3:   Anschlussschema, PTH-6201-DF

Abb. 4:   Konfigurationsbeispiel

Abb. 5:   Ausrichtung von PTH

TROUBLESHOOTING

Symptom

Cause

Action

Green LED not lit

No power supply

Check power supply
Check electrical connections
Check connectors

Defective PTH-6201-DF

Replace PTH-6201-DF

Yellow LED not lit

Modbus connection broken/

short-circuited

Check electrical connections 

along entire length of Modbus

Incorrect address

Set correct Modbus address on 

address selector in PTH-6201-

DF

Incorrect communication speed Set correct communication: 

38.4 kbaud, 1 start bit, 8 data 

bits, 1 stop bit, no parity

Defective PTH-6201-DF

Replace PTH-6201-DF

Negative measured value 

displayed

Tubes interchanged

Exchange tubes on plus (+) and 

minus (-) tube connectors.

Defective PTH-6201-DF

Replace PTH-6201-DF

Measurement deviation

PTH-6201-DF positioned where 

temperature is outside specified 

temperature range

Adjust ambient temperature to 

range specified in these instruc-

tions

No or reduced flow through 

pressure measurement tubes

Check that pressure measure-

ment tubes are correctly fitted

Zero pressure at measuring 

points

Start fan

Defective PTH-6201-DF

Replace PTH-6201-DF

Zero point deviation

Zero calibration not carried out

Depressurise PTH-6201-DF, if 

necessary by removing both 

pressure tubes, and carry out 

zero calibration.

Defective PTH-6201-DF

Replace PTH-6201-DF

Содержание PTH-6201-DF

Страница 1: ...ap lock beside the tube con nectors Modbus is connected to PTH 6201 DF via the four screw terminals which besides being used for Modbus connection are also used for loop connections to other Modbus co...

Страница 2: ...en und so zu befestigen dass Schwingun gen vermieden werden Mit R cksicht auf eine optimale Druckmessung ist die Messung dort vorzunehmen wo die ger ingste Gefahr turbulenter Str mung vorhanden ist da...

Страница 3: ...auschen Messabweichung Die Umgebungstemperatur des PTH 6201 DF liegt au erhalb des angegebenen Temperatur bereichs Umgebungstemperatur an den in dieser Anleitung angegebe nen Bereich anpassen Fehlende...

Страница 4: ...fix sur une surface solide et de niveau avec deux vis Le PTH 6201 DF peut tre mont dans toute orientation sans affecter d favorablement sa pr cision Le PTH 6201 DF fonctionne galement avec seu lement...

Страница 5: ...ur des adresses entre 0x50h et 0x5Fh L adresse peut tre r gl e par les interrupteurs d adresse l int rieur du PTH 6201 DF Adresses Modbus Encodeur ID 0 0x59 89 dec 8 0x53 83 dec 1 0x56 86 dec 9 0x54 8...

Страница 6: ...ig 2 Position of transmitter in relation to bends and branches BR956A03 BR0875A02 PTH Regulator PTH Fig 4 Example of configuration BR875A02 PTH BR956B15a Fig 3 Wiring diagram PTH 6201 DF 2021 OJ Elect...

Страница 7: ...2021 OJ Electronics A S 7...

Страница 8: ...ark is registered and belongs to OJ Electronics A S 2021 OJ Electronics A S 8 OJ ELECTRONICS A S Stenager 13B DK 6400 S nderborg Tel 45 73 12 13 14 Fax 45 73 12 13 13 oj ojelectronics com www ojelectr...

Отзывы: