COMMISSION REGULATION
COMMISSION REGULATION (EU)
No 813/2013 ANNEX II TABLE 2
Information requirements for heat pump
space heaters and heat pump combination
heaters
supplier’s name or trademark
Oilon Oilon Oilon Oilon Oilon Oilon
supplier’s model identifier
ECO
6 07
Cube
6 07
ECO
8 07
Cube
8 07
ECO
10 03
Cube
10 07
ECO
13 07
Cube
13 07
ECO
17 07
ECO
21 07
Air-to-water heat pump
-
-
-
-
-
-
Water-to-water heat pump
✓
✓
✓
✓
✓
✓
Brine-to-water heat pump
✓
✓
✓
✓
✓
✓
equipped with a supplementary heater
✓
✓
✓
✓
✓
✓
Combination heater
CUBE:
✓
ECO:
-
CUBE:
✓
ECO:
-
CUBE:
✓
ECO:
--
CUBE:
✓
ECO:
-
ECO:
-
ECO:
-
AVERAGE TEMPERATURE APPLICATION
(BRINE 0/−3 °C, WATER 47/55 °C),
AVERAGE CLIMATE CONDITIONS
Rated heat output
Prated
kW
5
7
9
12
15
19
Seasonal space heating energy efficiency
s
%
145
150
157
157
156
159
Bivalent temperature
T
biv
°C
-
-
-
-
-
-
Cycling interval capacity for heating
P
cych
kW
-
-
-
-
-
-
Degradation coefficient
Cdh
–
0.9
0.9
0.9
0.9
0.9
0.9
DECLARED HEATING CAPACITY AND
COEFFICIENT OF PERFORMANCE
FOR PARTIAL LOAD AT AN INDOOR
TEMPERATURE OF 20 °C AND THE
OUTDOOR TEMPERATURES AND FLOW
TEMPERATURES GIVEN BELOW (BRINE
0/-3 °C)
Outdoor temperature −7 °C, flow +52 °C
Pdh
kW
5.2
6.9
9.3
11.8 15.6 19.4
Outdoor tempe2 °C, flow +42 °C
Pdh
kW
5.4
7.2
9.7
12.4 16.4 20.4
Outdoor tempe7 °C, flow +36 °C
Pdh
kW
5.6
7.3
10.0 12.7 16.9 21.0
Outdoor tempe12 °C, flow +30 °C
Pdh
kW
5.7
7.5
10.2 13.0 17.4 21.6
Outdoor temperature −7 °C, flow +55 °C
Pdh
kW
5.1
6.8
9.1
11.7 15.4 19.1
Bivalent temperature
T
biv
°C
-
-
-
-
-
-
Operating limit temperature (outdoor
temperature)
TOL
°C
-
-
-
-
-
-
DECLARED COEFFICIENT OF
PERFORMANCE FOR PARTIAL LOAD AT
AN INDOOR TEMPERATURE OF 20 °C AND
THE OUTDOOR TEMPERATURES AND
FLOW TEMPERATURES GIVEN BELOW
(BRINE 0/-3 °C)
Outdoor temperature −7 °C, flow +52 °C
COPd -
2.88 2.96 3.10 3.08 3.10 3.20
Outdoor tempe2 °C, flow +42 °C
COPd -
3.70 3.80 3.97 3.99 3.96 4.05
Outdoor tempe7 °C, flow +36 °C
COPd -
4.29 4.46 4.63 4.65 4.59 4.67
Outdoor tempe12 °C, flow +30 °C
COPd -
4.97 5.34 5.41 5.41 5.34 5.38
Outdoor temperature −7 °C, flow +55 °C
COPd -
2.67 2.75 2.87 2.85 2.88 2.98
Bivalent temperature
T
biv
°C
-
-
-
-
-
-
Operating limit temperature (outdoor
temperature)
TOL
°C
-
-
-
-
-
-
POWER CONSUMPTION
When the unit is in OFF mode
P
OFF
kW
0.00 0.00 0.00 0.00 0.00 0.00
When the thermostat is not requesting heat
P
TO
kW
0.01 0.01 0.01 0.01 0.01 0.01
M8006 2123EN
53 (54)