Brine pump
Keeps running
You can set the brine pump to keep running continuously for a few days after
commissioning. The setpoint value is in days.
4.10 Final settings
Manual control
The manual control function allows you to manually switch valve positions and, for example, turn on the
brine pump or condenser pump to facilitate bleeding the corresponding circuit. The function can also be
activated from the
Service
menu.
Start heat pump
Start the heat pump either using this option or later from the
Service
menu.
Off
The heat pump is switched off.
In use
The heat pump is switched on.
Operating mode
Additional heater only
Only the unit’s internal electric immersion heater is used for heating. The
compressor and the brine circuit are not in use.
Setup finished
Hide initial setup
menu
Once the commissioning process is complete, hide the
Initial setup
menu. If
necessary, display the menu again from the
Service
menu.
4.11 Design outdoor temperature
The information below applies to Finland, and is provided for reference only.