Current DC
Resistance
Ω
Diode and continuity test
Range Resolution
Accuracy
Various
200
μ
A
0,1
μ
A
±(1,5%+3)
Input current: 10A (max 10 sec)
Overload protection:
0,2A/250V fuse
10A unfused
2mA
1
μ
A
20mA
10
μ
A
200mA
100
μ
A
10A
10mA
±(2,0%+5)
Range Resolution
Accuracy
Various
200
Ω
0,1
Ω
±(0,8%+5)
Overload protection
max 250V DC or AC peakvalue
Note:
at 200
Ω
range, the
resistance of the test leads
should be deducted from the
measured value.
2k
Ω
1
Ω
±(0,8%+3)
20k
Ω
10
Ω
200k
Ω
100
Ω
20M
Ω
10k
Ω
±(1,0%+15)
Range
Display
Condition
Various
Positive
voltage drop of
diode
The positive DC
current is ± 1mA,
negative voltage
is ± 3V
Overload protection:
Max 250VDC or AC peak value
Warning: Do not input any vol-
tage at this range for
safety reasons.
Buzzer sound:
resistance is
less than
(70 ± 20)
Ω
Open voltage is
±3V
www.ohmeron.com
- 15 -