運転中の表示

/

Display during operation

 

↑/↓ボタンで表示を切り替えることができます。

 

The Up/Down arrow buttons cycle through indications during operation.   

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

(4)

パラメータ設定モード

/

Parameter Setting mode

 

停止中に

MODE SELECT

ボタンを押すとパラメータ設定モードに移行します。

 

↑/↓ボタンで設定項目を切り替えます。

 

To move to the Parameter Setting mode, press the MODE SELECT button during stoppage. 
The Up/Down arrow buttons cycle through parameters. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

OP      **.**kPa 

SP      **.**kPa 

DP      **.**kPa 

EP      **.**kPa 

外部圧

 

External pressure 

吸込圧

 

Suction pressure 

差圧

 

Differential pressure 

排気圧

 

Exhaust pressure 

 

Blower      ***.*

 

ブロア周辺温度

 

Runtime      ******h 

積算稼働時間(リセット可)

 

リセット後からの稼働時間を表示します。

 

Accumulated run time (resettable) 

Indicates run time accumulated since 

the last resetting. 

Total      ******h 

実働時間(リセット不可)

 

トータルの稼働時間を表示します。

 

Actual run time (not resettable) 
Indicates the total run time. 

Motor      ******

rpm

 

モータ回転数

 

Motor revolution 

[Com Setting] 

[Volume Down ST] 

[Other Setting] 

[Error Data] 

通信フォーマット設定モード

 

Communication Format Setting mode

 

風量不足お知らせタイミング設定モード

 

Air Volume-Down Alert Timing Setting mode

 

その他の設定モード

 

Other Setting mode

 

エラー履歴モード

 

Error History mode 

2

次フィルタ

 

Secondary filter

 

モータ

 

Motor

 

1

次フィルタ

 

Primary filter

 

3

次フィルタ

 

Tertiary filter

 

ホース

 

H

o

se

 

外部圧

 

External

 

pressure

 

排気圧

 

Exhaust

 

pressure

 

差圧

 

Differential

 

pressure

 

吸込圧

 

Suction 

 

pressure

 

ブロア周辺温度

 

Temperature

 

around blower

 

圧力表示

 

Pressure indication

Содержание DUST CUBE

Страница 1: ...uction Manual OSK 060ACC AT3 Thank you for purchasing our dust collector DUSTCUBE For safety and trouble free operation please read this instruction manual carefully and keep it at hand for future ref...

Страница 2: ...s instruction manual contents general instructions for safety installation operation and maintenance works However please understand that they may not cover all possible contingencies Always keep in m...

Страница 3: ...the following substances Flammable matters including gasoline thinner benzene kerosene and organic solvents Explosive materials like aluminum magnesium titanium zinc and epoxy and any matters which t...

Страница 4: ...mospheric conditions of Pollution Degree 2 industrial areas The altitude of the site of use should be lower than 1000 m Transportation and storage temperatures should be within the range from 10 to 60...

Страница 5: ...and there is no damage with any of them Should any problem be found please contact your supplier immediately Air intake Detachable flange Filter case Primary filter Collision plate Secondary filter A...

Страница 6: ...00mm to 2000mm height from the floor Be sure to install the unit the right way up within the tolerance of 2 deg perpendicularly and horizontally Suction pipes should be routed by the most direct way S...

Страница 7: ...and remove the primary secondary and the tertiary filters Pull the insulating sheet in the arrow direction off the battery cover The direction for pulling off the insulating sheet depends on the unit...

Страница 8: ...without filter or with a clogged or damaged filter It will allow foreign matter to enter Avoid pressing the keys repeatedly in quick succession Switch operation may be disabled In such case turn off t...

Страница 9: ...the Left or Right arrow button changes the suction power to the next lower or higher level During parameter setting mode each pressing of the Left or Right arrow button moves the cursor left or right...

Страница 10: ...N4 for low air volume Go through the following steps to register initial pressures Perform the wiring and piping of the DUSTCUBE Start the unit at a desired suction power level ENTER 3 Initial DP Get...

Страница 11: ...to normal operation Initial DP Clr On completion of clearing the display shows the Initial DP Clr message and the unit returns to the stop state 6 5 Display indication 1 State transition 2 Display dur...

Страница 12: ...st pressure Blower Runtime h Accumulated run time resettable Indicates run time accumulated since the last resetting Total h Actual run time not resettable Indicates the total run time Motor Motor rev...

Страница 13: ...ing Setting mode Volume Down ST ENTER 50 3 Down to 50 Press the ENTER button The current setting appears The default is 50 displayed as 3 Down to 50 30 70 Press the Up Down arrow buttons to select a t...

Страница 14: ...TER button to determine the value Set the value in this order hours minutes and seconds MODE SELECT To exit this mode press the MODE SELECT button to return to normal mode 2 Accumulated Run Time Reset...

Страница 15: ...reset press the ENTER button 1 START The display shows 1 START for reconfirmation ENTER Press the ENTER button to reset the setpoints and move the unit to normal mode 4 Error History mode 4 OFF The e...

Страница 16: ...WARN5 Outputs signal when WARN2 WARN4 or WARN5 has occurred NPN open collector output Remote control operation input signal Red White Short circuit this and the pin to start remote operation The opera...

Страница 17: ...devices by pressing ON OFF buttons on the operation panel Disconnect the pin and ON OFF Operate by the ON OFF button on the operation panel Capacity level Voltage Apply the intermediate value of each...

Страница 18: ...n circuit not to exceed the rating Pin Pin 100mA Unit side Customer side Unit side Customer side 1 5 0 2V Output Voltage 1 to 5 0 2V Reference circuit Unit side Customer side DC24V Max DC50V LOW Curre...

Страница 19: ...MODE SELECT button to move to the Error History mode If two or more errors or warnings occurred the number of occurrence is displayed in the left of the error number No If two or more errors or warnin...

Страница 20: ...nd the blower is close to the error threshold Blinking Operation continues 7 7 Remedy the error referring to in 7 7 Troubleshooting WARN2 Filter replacement time expired Operation continued at low air...

Страница 21: ...the filter direction in its installation Do not use a clogged worn or broken filter Use of such filter will allow the absorbed dust to disperse again into the air and can damage nearby electronic devi...

Страница 22: ...r in the DUSTCUBE and close the Filter case 3 Replacement of Tertiary filter Release the two draw latches to open the Filter case Then take out the Collision plate Primary filter and the Secondary fil...

Страница 23: ...without replacing the button battery after WARN7 Battery voltage low has generated However it has a risk of erasing setting data when the power is turned off Apply power to the unit Loosen the two dr...

Страница 24: ...end appropriate Any errors or warnings is not indicated on the display Check the following matters at least once a month Are the filters securely fit in each casing 7 4 Replacing fuse Replace a fuse i...

Страница 25: ...t may be active Turn off the main power and resume operation after 30 minutes Filters are not fitted Install the all filters correctly Draw latch is disengaged Engage the draw latch Poor suction power...

Страница 26: ...consumption Working temperature Working humidity 80 RH without condensation Noise Characteristic A Max suction air temperature Body color Main body Munsell 10B7 6 Cover Munsell N9 3 Weight Accessorie...

Страница 27: ...mote cable 5m Detachable flange for 38 hose Detachable flange for 50 hose Warranty This product is covered with 1 year warranty from the date of shipment provided that such warranty does not apply to...

Страница 28: ...000 21 TEL 053 522 5572 FAX 053 522 5573 7000 21 Nakagawa Hosoe Kita Ku Hamamatsu Shizuoka 431 1304 Japan TEL 81 53 522 5562 FAX 81 53 523 2362 3 2020 7 3rd edition The contents of this manual is as o...

Отзывы: