■設置方法  Installation

 

注意  Caution

 

 
 
 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
ミストキャッチは必ず上下を確認して、水平、垂直(±2°)に取付けてください。 

→ドレンの排出がスムーズに行われず、外に撒き散らす可能性があります。 

Place the MISTCATCH right side up and fix it perpendicularly 
and horizontally within a tolerance of ±2° as shown right. 
  - Failure to this may lead to scattering of water due to poor drainage. 

 

保守、点検及び円滑な空気循環のために周囲に500mm以上の空間を確保してください。 
Keep at least 500mm or more space around a MISTCATCH in order to assure good ventilation and easy 
access for maintenance service. 

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

 
 
 

 

 

 

吸引口がオイルミストの発生源に近い場合は、衝突板などを設けて、

 

多量のオイルミストや切り屑を吸引しないようにしてください。

 

  →多量のオイルミストを吸引すると、外に撒き散らす可能性があります。

 

Where the suction port is close to a mist source, provide 
a collision plate or other protective measures   
against inhaling excessive amount of oil mist or machining swarf.   
    - Over-inhaling may cause scattering of oil. 

 

粒子径の小さいオイルミスト(油性オイルミストなど)を吸引する場合はミストキャッチ内部で捕集しきれず、 
排気口よりミストが吹き出してしまう可能性があるため、アフターフィルタ(別売り)をご使用ください。 
For inhaling extra fine particles like water-insoluble mist, use of the optional After Filter is recommended 
for prevention of possible blow-off of untrapped particles. 

 

衝突板

 

Collision 
plate

 

 

ミストキャッチへ 
Into MISTCATCH 

Содержание MIST CATCH OMC-F105A

Страница 1: ...ochure contains general instructions for safety handling installation operation and maintenance of MISTCATCH However please understand that they may not cover all possible contingencies Always keep in...

Страница 2: ...Contents Safety precautions Part names Installation Operation Maintenance Specifications Option Maintenance parts Warranty...

Страница 3: ...ortant matters for safety and therefore have to be observed without fail The marks and the symbols in this manual have the meanings as described below Danger Improper handling may result in serious in...

Страница 4: ...t and cutting powder 50 Hot air exceeding 50 Liquid in plenty Substances which accelerate rusting of metals or aging of plastics Failure to the above may cause fire breakage or electric leak This prod...

Страница 5: ...free from condensation Never transport MISTCATCH with being mounted on a machine a mounting stand and the like Shocks vibrations and excessive load should be avoided during transportation Failure to t...

Страница 6: ...assure good ventilation and easy access for maintenance service Where the suction port is close to a mist source provide a collision plate or other protective measures against inhaling excessive amoun...

Страница 7: ...4pieces of M8 Anti vibration rubbers Be careful not to over tighten the anti vibration rubbers Drill the mounting holes to fit the enclosed duct flange Connect the duct hose and fix it with the fixin...

Страница 8: ...to avoid liquid pooling Connect the drain hose to the drain pipe Caution For assuring smooth drainage route the hose straight downward without flattening or rolling Faulty drainage may be a cause of s...

Страница 9: ...lace Motor will not properly work if wrongly wired Make sure that rotation of motor is as indicated by an arrow on the MISTCATCH Tighten the cable gland CAPCON to fix the cables Put the cover on the t...

Страница 10: ...the condition of installation like attachment of an after filter or the length or routing of duct hose it may not show the maximum level even in the initial state Maintenance Caution Turn off power a...

Страница 11: ...he foreign matter Stop using the product and contact the supplier Note In case any trouble occurred during operation turn off power immediately and contact the supplier Replacement of Filter Filter is...

Страница 12: ...port covers back Note Place the suction port cover so the arrow sticker is shown on top Chip separator maintenance Loosen the clamps on top and bottom of the Chip separator to remove the lid Take out...

Страница 13: ...oise Characteristic A 57 dB A 63 dB A 66 dB A Max suction air temp 50 Applicable standards Machinery directive EN ISO 12100 EN60204 1 Environmental standard RoHS2 Suction port diameter 100 mm 125 mm 1...

Страница 14: ...Outline drawing...

Страница 15: ...0A CS OMC F120 F40 2 OMC AF 500L Replacement parts OMC F105A OMC F110A OMC F120A Primary filter OMC F105 F10 OMC F110 F10 OMC F120 F10 Secondary filter 3pcs set OMC F105 F20 OMC F110 F20 OMC F120 F20...

Страница 16: ...out of our responsibility should be treated at the customer s cost 431 1304 7000 21 TEL 053 522 5572 FAX 053 522 5573 7000 21 Nakagawa Hosoe Kita Ku Hamamatsu Shizuoka 431 1304 Japan TEL 81 53 522 55...

Отзывы: