The care-e-vac

®

3 is a portable medical aspirator to suction fluids or foreign bodies from a 

patient. The medical device may be powered by a 120 VAC outlet or 12 VDC source. It is 
equipped with an internal battery. The primary intended use of the care-e-vac 3 is to aspirate 
saliva, mucous, vomitous or other aspirant from the mouth and or airway to allow adequate 
respiration or ventilation of the patient. 

 

Dual power capabilities of the care-e-vac

®

3 is ideal for the following applications: 

 

●  Hospital crash cart suction 

●  Patient transport 

●  Surgi-center backup suction 

●  Emergency medical service 

●  Home health care/nursing homes 

 

The care-e-vac

®

3’s suctioning capabilities are generated by a diaphragm pump. It comes 

equipped with a disposable in-line hydrophobic filter, 14” of tubing, and a disposable 800 cc 
collection canister. 

 

 

This manual covers the care-e-vac

®

3 in the following sections: 

 

I. 

Definitions and Symbols Legend 

Page 3

 

II. 

Instructions for Use 

Page 4

 

III. 

Maintenance 

Page 5

 

IV. 

Troubleshooting / Removal of Service Components 

Page 8

 

V. 

Device Specifications 

Page 9

 

VI. 

800 cc Canister Instructions 

Page 10

 

VII. 

OSHA Hazard Communications Standard 

Page 11

 

VIII. 

Warranty 

Page 12

 

IX. 

Accessories 

Page 13

 

X. 

Service Parts 

Page 13

 

XI. 

EMC Information 

Page 14

 

XII. 

Environmental Conditions 

Page 14

 

XIII. 

General Warnings and Cautions 

Page 14

 

XIV.  Battery Recycling and Disposal 

Page 14

 

XV. 

Electromagnetic Compatibility Declarations 

Page 15

 

 

 

For additional information, please contact Ohio Medical Customer Service Department at  

866-549-6446 

or your local Ohio Medical Dealer. 

Содержание care-e-vac 3

Страница 1: ...PORTABLE SUCTION ASPIRATOR PART NUMBER 758000 OPERATOR MAINTENANCE M A N U A L ...

Страница 2: ... homes The care e vac 3 s suctioning capabilities are generated by a diaphragm pump It comes equipped with a disposable in line hydrophobic filter 14 of tubing and a disposable 800 cc collection canister This manual covers the care e vac 3 in the following sections I Definitions and Symbols Legend Page 3 II Instructions for Use Page 4 III Maintenance Page 5 IV Troubleshooting Removal of Service Co...

Страница 3: ...ll operate at its maximumperformance WARNING Red Light LOW The unit will continue to operate for less than 10 minutes and should be recharged immediately Amber Light CHARGING AC Unit is properly connected to the power source This light will remain illuminated as long as the unit is connected to the powersource This device should be used only by qualified medical personnel properly trained in medic...

Страница 4: ...d by placing the unit on its side and locating the plastic clamp which secures the bracket Using a Phillips head screwdriver loosen DO NOT REMOVE the screws and adjust the bracket to the desired position Retighten the screws The care e vac 3 is designed to use any size collection device up to 1200 cc However if you are not using an Aeros disposable collection canister make sure the collection de v...

Страница 5: ...ter and all suctiontubing 2 Wipe the surface of the unit clean with a mild antiseptic and a clean soft cloth Do not allow any cleaning solution to spill into the vents on theunit 3 Turn unit on to check the condition of the battery If the LOW Red LED illuminates recharge the battery Verify the unit can regulate to FULL VAC as outlined in sec tion II A 3 4 Place a new collection canister suction tu...

Страница 6: ...fications Section B Vacuum Regulator Cleaning The suction regulator may accumulate aspirant after the pump has been in service for an extended period of time When disassembling the pump for cleaning it is suggested that the regulator also be cleaned as a preventativemeasure 1 Remove the regulator by disconnecting the silastic tubing and loosen the locknut make note of the orientation of all tubing...

Страница 7: ...e the orientation of the battery beingreplaced D WARNING Decontamination In the event that contaminated fluids have ingressed beyond the hydrophobic filter follow the procedure outlined below In addition always use proper protective gear i e rubber latex gloves goggles etc when in contact with contaminated parts 1 Remove the device from the AC power source prior to cleaning and clean the interior ...

Страница 8: ...ard 6 Battery wires are on wrong termi 6 Switch battery wires to proper terminals nals Low or no vacuum on 1 Improper tubingconnection or 1 Check all external vacuum parts for running unit crimped tube in the system crimped tubing If still no vacuum check all internal tubingconnections 2 Mechanical shut off is activated in 2 If the mechanical shut off has been acti the collection canister vated on...

Страница 9: ... clockwise to remove 6 Canister Bracket Remove all six 6 cover screws and slide covers apart Loosen screws that hold bracket in place Slide bracket out and replace with new bracket 7 Silencer Remove all six 6 screws and slide covers apart Unscrew silencer from pump using a 3 8 box wrench 8 Regulator Follow directions outlined in vacuum regulator cleaning SectionIII B V Device Specifications PUMP 1...

Страница 10: ...ections to ensure they are properly sealed Note Test the assembly for vacuum leaks by turning on vacuum source and occluding the patient tubing with finger or thumb 6 Tohelp prevent fluid contamination to vacuum system ALWAYS make sure the vacuum line is attached to the vacuum port Disposal 1 Turn off vacuum source and disconnect all tubing 2 Seal vacuum and patient ports with attached port caps 3...

Страница 11: ... radioactive biological toxic or hazardous chemical substances the following information Our facility does not have the ability to properly identify all the possible hazardous substances which could be present in our products returned for service Since we cannot properly identify all hazards we do not have the protective equipment and means to safely repair these products when returned for service...

Страница 12: ...hts which may vary from state to state To obtain service within the three year period first contact your authorized OHIO MEDICAL dealer or OHIO MEDICAL Customer Service Department Before returning any unit to the factory proper return authorization must first be obtained from the OHIO MEDICAL Customer Service Department Labor to repair any unit proved to be defective within the three year period w...

Страница 13: ...ther than those listed above may result in Part Number Description 749144 REPLACEMENT SEALED LEAD ACID BATTERY AI4080000 CANISTER COLLECTION 800cc AI4080010 CANISTER ONLY REPL KIT 800 cc LID INCL PACKAGE OF 10 AI4080025 CANISTER ONLY REPL KIT 800 cc LID INCL PACKAGE OF 25 AI4120000 CANISTER COLLECTION 1200 cc AI4120010 CANISTER ONLY REPL KIT 1200 cc LID INCL PACKAGE OF 10 AI4120025 CANISTER ONLY R...

Страница 14: ...e page 16 XII Environmental Conditions Specifications Storage Temperature Range 40ºC to 60ºC 40 F to 140 F Storage Relative Humidity Range 40 to 70 Non Condensing Pressure 50 106 kPa Operating Temperature Range 20ºC to 50ºC 4o F to 122 F Operating Relative Humidity 95 Non Condensing XIII General Warnings 1 To reduce the risk of electric shock do not remove cover Refer servicing to qualified person...

Страница 15: ...d no closer to any part of the care e vac 3 including cables than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Recommended separation distance Calculated RF 3 Vrms 3 Vrms d 1 2 P IEC 61000 4 6 150 kHz to 80 MHz Radiated RF 3 V m d 1 2 P 80 MHz to 800 MHz IEC 61000 4 3 80 MHz to 2 5 GHz 3 V m d 2 3 P 800 MHz to 2 5 GHz where P is th...

Страница 16: ...OhioMedical 866 549 6446 Fax 847 855 6218 1111 Lakeside Drive Gurnee IL 60031 www ohiomedical com 550542 Rev 6 06 2016 ...

Отзывы: