background image

EN-2 YJ 

Series 

 

YJ Scale

 

Mark  

Standard  

 

This product conforms to the EMC Directive 

2004/108/EC

, the Low Voltage Directive 

2006/95/EC

 and the Non-Automatic Weighing Directive 2009/23/EC. The complete 

Declaration of Conformity is available from Ohaus Corporation. 

  

AS/NZS4251.1 Emission; AS/NZS4252.1 Immunity  

 

 
 

 
 

 

Disposal 

In conformance with the European Directive 2002/96/EC on Waste Electrical and Electronic 
Equipment (WEEE) this device may not be disposed of in domestic waste. This also applies 
to countries outside the EU, per their specific requirements. 
Please dispose of this product in accordance with local regulations at the collecting point 
specified for electrical and electronic equipment. 
If you have any questions, please contact the responsible authority or the distributor from 
which you purchased this device. 
Should this device be passed on to other parties (for private or professional use), the content 
of this regulation must also be related. 
Thank you for your contribution to environmental protection.

 

 

 

 

 
 
NOTE:  This equipment has been tested and found to comply with the limits for a Class A digital device, 
pursuant to Part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against 
harmful interference when the equipment is operated in a commercial environment.  This equipment 
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the 
instruction manual, may cause harmful interference to radio communications.  Operation of this equipment in 
a residential area is likely to cause harmful interference in which case the user will be required to correct the 
interference at his own expense. 
 
This Class A digital apparatus complies with Canadian ICES-003. 
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. 

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176

TestEquipmentDepot.com 

Содержание YJ103

Страница 1: ...YJ Carat and Gold Scales Instruction Manual 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com ...

Страница 2: ...er parties for private or professional use the content of this regulation must also be related Thank you for your contribution to environmental protection NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment ...

Страница 3: ...he power adapter input voltage matches the local power supply voltage 1 2 Controls TABLE 1 1 CONTROL FUNCTIONS Key Name Function On Off Primary function If scale is Off turn On If scale is On turn Off Primary function Enters scale menu Light Menu Function Advances to next menu item Primary function Advances to next available unit Units Menu Function This key is used to reject the displayed setting...

Страница 4: ...tlet see Figure 2 1 and the input jack to the back of the scale see Figure 2 2 Figures 2 1 Figure 2 2 2 5 Initial Calibration Have the appropriate calibration masses available before beginning calibration See Table 6 1 Power on the scale by pressing On Press Light button and SCALE is displayed Press Tare and span mass is displayed Press Tare the span mass value flashes Put the indicated calibratio...

Страница 5: ...E LinE Backlight Menu FI F2 F3 Auto Off Menu off 60 S 120 S 180 S 240 S 300 S 360 S 420 S 480 S 540 S TABLE 4 1 MENU Note Default settings are shown in bold 4 2 Menu Navigation Enter Menu Press and release Light The SCALE menu will be displayed Each menu is entered by pressing Tare Advance to the next main menu by pressing Light Changing Settings Press Units to reject the displayed setting and adv...

Страница 6: ...bleshooting The following table lists common problems and possible causes and remedies If the problem persists contact Ohaus or your authorized dealer TABLE 5 1 TROUBLESHOOTING Symptom Possible Cause Remedy Cannot turn on No power to scale Empty or incorrectly installed batteries Verify AC adapter connections and voltage Replace batteries check polarity Poor accuracy Improper calibration Unstable ...

Страница 7: ...ATA 6 1 Specifications TABLE 6 1 SPECIFICATIONS Model No YJ103 YJ152 YJ102 YJ301 YJ501 100ct 150ct Capacity 20g 30g 100g 300g 500g 0 005ct 0 01ct Readability 0 001g 0 002g 0 01g 0 1g 0 1g Linearity 1 d Repeatability 1 d Operating Temperature Range 10 to 30 C Weighing Units Gram Carat Grain Ounce Ounce Troy Pennyweight Tare Range To capacity by subtraction Stabilization Time seconds 3 Recommended S...

Страница 8: ... material penetrating to the inside of the product or as a result of service or modification by other than Ohaus In lieu of a properly returned warranty registration card the warranty period shall begin on the date of shipment to the authorized dealer No other express or implied warranty is given by Ohaus Corporation Ohaus Corporation shall not be liable for any consequential damages As warranty l...

Отзывы: