background image

 

 
 
 

Range

r™ 4000 Series 

Instruction Manual 

 
 
 
 
 
 
 
 
 
 
 

 

Содержание Ranger R41MEB

Страница 1: ...Ranger 4000 Series Instruction Manual...

Страница 2: ......

Страница 3: ...e safety precautions Verify that the AC input voltage printed on the data label matches the local AC power supply Only connect the power cord to a compatible grounded electrical outlet Do not position...

Страница 4: ...s heat sources or rapid temperature changes Allow sufficient space around the scale 2 4 Leveling the Equipment The Ranger Series has a level indicator as a reminder that the scale should be leveled fo...

Страница 5: ...in table 3 2 will remain lit The scale can be operated during charging and the battery is protected against overcharging For maximum operating time the battery should be charged at room temperature D...

Страница 6: ...s the accumulation when the accumulation information is displayed Secondary Function Long Press Off Turns the scale Off Units Changes the weighing unit Mode Allows changing the application mode Menu E...

Страница 7: ...l 11 Pound Ounce Pound Ounce symbols 5 Preset Tare Tare symbols 12 Kilogram gram symbols 6 Pointer symbols 13 Pieces symbol 7 Accumulation symbol 14 Percent symbol The colored LED indicators on the le...

Страница 8: ...gh is displayed 2 If required place an empty container on the pan and press Tare 3 Add sample to the pan or container The display shows the weight of the sample 3 4 Percent Mode This mode measures the...

Страница 9: ...d number of pieces on the pan then press Yes to calculate the APW The display shows the piece count 7 Add additional pieces until the desired count is reached 8 To clear the stored APW press and hold...

Страница 10: ...hen display Set Lo Press Yes to view the Low limit value Press Yes to accept or No to edit the Low limit value The stored value then displays with the first digit highlighted 000 000 Repeatedly press...

Страница 11: ...han the UNDER limit Add material to the scale until it is within the ACCEPT green range Negative Check Negative check is used to determine when the material removed from the scale is within the target...

Страница 12: ...ncrements 3 After completed countdown the average weight will be displayed The tilde symbol will blink indicating that the current weight is being held 4 Remove the load and the display will reset aft...

Страница 13: ...ting select mMaNU If required place an empty container on the pan and press Tare Step i Put the weight 0 04 kg on the pan and press M key The icon indicator will keep flashing until the weight is remo...

Страница 14: ...vailable in all models 1 This menu item is only used in models with LED display When LEGAL FOR TRADE is set to ON Lock Switch in locked position the menu settings are affected as follows Calibration C...

Страница 15: ...accurate weighing results Before performing the calibration be sure to have the appropriate calibration weights as listed in table 4 1 Ensure that the LFT switch calibration lock is set to unlocked po...

Страница 16: ...the top of the current menu 4 3 Setup Menu Enter this menu to set scale parameters Reset reset Reset the Setup menu to factory defaults NO not reset YES reset Power on unit pwWr UN Set the unit of me...

Страница 17: ...UNDER the beeper will sound when the weight is above the Over setting OVER the beeper will sound when the weight is below the Under setting or above the Over setting Beeper Key BP key Set whether the...

Страница 18: ...the display will maintain zero until a change of 1 divisions per second has been exceeded 3d the display will maintain zero until a change of 3 divisions per second has been exceeded Light LIGHt LCD...

Страница 19: ...t Set the status OFF disabled ON enabled Count COUNt Set the status OFF disabled ON enabled Check CHECk Set the sub mode OFF disabled WEIGH weight mode PERCNT percent mode COUTN count mode Dynamic DYN...

Страница 20: ...le Only Stable Set the printing criteria OFF values are printed immediately ON values are only printed when the stability criteria are met Auto Print A Print Set the automatic printing functionality O...

Страница 21: ...he printed data Result Set the status OFF disabled ON the displayed reading is printed Gross Set the status OFF disabled ON the gross weight is printed Net Set the status OFF disabled ON the net weigh...

Страница 22: ...ows XP Setup 1 Click Start Menu in Windows XP and click Settings open Control Panel 2 Double click Accessibility Options in Control Panel 3 Select the General tab 4 Check Use Serial Keys and click the...

Страница 23: ...ODD 7 data bits odd parity 7 NONE 7 data bits no parity 8 NONE 8 data bits no parity Stop bit stOP Set the number of stop bits 1 1 stop bits 2 2 stop bits Handshake H shake Set the flow control metho...

Страница 24: ...tion which can lock menu settings to prevent tampering Reset reset Reset the Lock menu to factory defaults NO no reset YES reset Lock Cal l CAL Set the status OFF Calibration menu is not locked ON Cal...

Страница 25: ...nu Press Yes to advance to the Calibration menu Press No to exit the menu and return to the current application mode 4 11 Additional Features The Weigh Below Hook is provided with the scale To use thi...

Страница 26: ...1 42 19 43 26 17 16 16 15 15 14 14 13 13 12 12 43 26 44 32 17 17 16 16 15 15 14 14 13 13 12 44 32 45 38 18 17 17 16 16 15 15 14 14 13 13 45 38 46 45 18 18 17 17 16 16 15 15 14 14 13 46 45 47 51 19 18...

Страница 27: ...ned in Section 4 2 3 Set the switch to Locked See figure 5 2 The Menu Lock switch limits changes to the Cal Setup Readout Unit and Print menus The switch in type approved models may set some scale set...

Страница 28: ...Ranger 4000 Series EN 26 Figure 5 2 Sealing Paper Seal Wire Seal Unlocked Locked with Paper Seal Locked with Wire Seal Lock Switch...

Страница 29: ...abled Enter menu and enable unit Battery icon flashing Low Battery error Connect scale to AC power and charge the battery Err 8 1 Power On Error Weight reading exceeds Power On Zero limit Err 8 2 Powe...

Страница 30: ...tween 8 00 AM and 5 00 PM EST An OHAUS product service specialist will be available to provide assistance Outside the USA please visit our web site www ohaus com to locate the OHAUS office nearest you...

Страница 31: ...00 g x 1 g 6 lb x 0 002 lb 96 oz x 0 04 oz 6 kg x 0 002 kg 6000 g x 2 g 15 lb x 0 005 lb 240 oz x 0 1 oz 15 kg x 0 005 kg 15000 g x 5 g 30 lb x 0 01 lb 480 oz x 0 18 oz 30 kg x 0 01 kg 30000 g x 10 g...

Страница 32: ...Print of displayed weight stable or unstable P Print displayed weight stable or unstable CP Continuous Print SP Print on Stability xS 0S Turn off Stable Only menu item and allow unstable print 1S Tur...

Страница 33: ...mands I1 Inquiry of SICS level and SICS versions I2 Inquiry of scale data I3 Inquiry of scale software version I4 Inquiry of serial number S Send stable weight value SI Send weight value immediately S...

Страница 34: ...s entered 1 23 kg T Tare value line If Printx Content Tare is ON and a tare value is entered REF WGT 0 012 kg Information line If Printx Content Info is ON MODE PERCENT Mode line If Printx Content App...

Страница 35: ...e left of most significant character if negative Unit Up to 5 characters left justified If the Unit in the Print Content menu was set to OFF the unit will be removed in the weight string and replaced...

Страница 36: ...e manufacturers work It comprises all tests according to the adopted European standard EN 45501 1992 paragraph 8 2 2 If national regulations limit the validity period of the verification the user of t...

Страница 37: ...can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Inc...

Страница 38: ...been damaged by accident or misuse exposed to radioactive or corrosive materials has foreign material penetrating to the inside of the product or as a result of service or modification by other than...

Страница 39: ...or del mundo Avec des bureaux dans le monde entier Weltweite Gesh ftsstellen Con uffici in tutto il mondo www ohaus com 30240427 P N 30240427 2020 OHAUS Corporation all rights reserved todos los derec...

Отзывы: