10

Weighing

Weighing

Weighing

Weighing

Weighing

1.

Press 

 to rezero the display.

2.

Place the object(s) or material to be
weighed on the pan.

3.

Wait for the stability indicator to ap-
pear before reading the weight.

STABILITY

INDICATOR

Checking Calibration

Checking Calibration

Checking Calibration

Checking Calibration

Checking Calibration

Before using the balance, calibration
should be checked. The balance has been
calibrated before shipment, however, it
could be influenced by factors such as:

Variations in the earths gravitational
field at different latitudes of the world.

Rough handling.

Changes in work location.

Height above sea level.

To check the balance’s calibration, place
a known mass on the center of the pan and
read the displayed weight.

If the displayed weight differs from the
known weight by more than acceptable
limits, refer to the Calibration Menu and
the Specifications at the rear of the manual.

ON

ON

ON

ON

ON

TARE

TARE

TARE

TARE

TARE

Содержание JR4KD

Страница 1: ...Instruction Manual PRECISION Standard Electronic Balances JR Series Ohaus Corporation 29 Hanover Road Florham Park NJ 07932 0900...

Страница 2: ...THIS EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXPENSE THIS DIGITAL APPARATUS DOES NOT EXCE...

Страница 3: ...8 OPERATION 9 Turning the Balance ON 9 Stabilization 9 Auto Range Models 9 Checking Calibration 10 Weighing 10 Taring 11 USING MENUS TO CONFIGURE THE BALANCE 12 CALIBRATION MENU 13 Calibration Menu Pr...

Страница 4: ...nit Selection 23 Lock Switch 24 End 25 MENU LOCK OUT PROTECTION 25 CARE AND MAINTENANCE 26 TROUBLESHOOTING 26 Error Codes 27 SERVICE INFORMATION 28 SPECIFICATIONS 29 PARTS INFORMATION 30 REPLACEMENT P...

Страница 5: ...contains a one piece solid state precision electronics PC board a seven digit LCD display which is 0 6 inches in height All Precision Standard series balances are factory set to measure in grams Each...

Страница 6: ...cludes draft shield and snap clamp this instruction manual your warranty card It is recommended to save the carton and packing material for storing transporting the balance or returning it for service...

Страница 7: ...ent that generates magnetic fields On an unlevel work surface Draft Shield JR120 JR200 and JR400D Draft Shield JR120 JR200 and JR400D Draft Shield JR120 JR200 and JR400D Draft Shield JR120 JR200 and J...

Страница 8: ...Place the pan on the support making sure the guide pin is in serted in the hole in the pan support AC Adapter AC Adapter AC Adapter AC Adapter AC Adapter Plug the molded connector of the adapter into...

Страница 9: ...0D and JR4KD JR400D and JR4KD JR400D and JR4KD JR400D and JR4KD JR400D and JR4KD Auto range balances offer both a fine range lower capacity higher readability and a coarse range higher capacity lower...

Страница 10: ...ibration shouldbechecked Thebalancehasbeen calibrated before shipment however it could be influenced by factors such as Variations in the earths gravitational field at different latitudes of the world...

Страница 11: ...Its weight will be displayed 2 Press The display will show zero and the container s weight will be stored in memory 3 Add material to the container As ma terial is added its net weight will be display...

Страница 12: ...play menus which enable you to calibrate and configure the balance for your specific operating requirements Calibration Menu Calibration Menu Calibration Menu Calibration Menu Calibration Menu Used to...

Страница 13: ...s weighing range and a weight value at or near the balance s specified capacity The following table shows the sequence in which submenus appear on the Calibration menu Calibration Weights Calibration...

Страница 14: ...d on the pan NOTE NOTE NOTE NOTE NOTE Do not disturb the balance when C is displayed Disturbances will result in improper calibration 5 Place the required weight on the pan and press The display will...

Страница 15: ...start the Linearity Cali bration Procedure When the is released C 0g will be displayed indicating that no weight should be in the pan 4 Press The display will show C followedbythevalueoftheweight whic...

Страница 16: ...followed by the next weight to be placed on the pan Do not disturb the balance when C is displayed Disturbances will result in improper calibration 7 Place the required weight on the pan then press Th...

Страница 17: ...menu has been locked out Specifies the averaging level Specifies the desired stability range Sets Auto Zero threshold Used to exit the Setup menu and store your selections User Menu Protection User Me...

Страница 18: ...ccess a submenu 1 Repeatedly press until the de sired submenu is displayed 2 Press to select the displayed submenu NOTE NOTE NOTE NOTE NOTE You must use END to store any changes you make to the User m...

Страница 19: ...submenu to display the current setting 2 Press to change the setting Press to accept the displayed setting When is released AL will be dis played again and the Setup menu will be returned AVERAGING LE...

Страница 20: ...splayed setting When is released Stb will be dis played again and the Setup menu will be STABILITY RANGE STABILITY RANGE STABILITY RANGE STABILITY RANGE STABILITY RANGE 5d smallest range stability ind...

Страница 21: ...emory if you use are only stored in memory if you use are only stored in memory if you use END END END END END To exit the User menu and store your settings press when End is dis played When is releas...

Страница 22: ...lock out the Setup menu refer to the section titled Menu Lock Out Protection NOTE NOTE NOTE NOTE NOTE If SAFE is displayed the Setup menu has been locked out Settings may be viewed but not changed Se...

Страница 23: ...accept the displayed status When is released the display will show the next unit indica tor with the current status 5 Set each unit ON or OFF as in step 3 Hong Kong Singapore Taiwan OFF OFF OFF OFF OF...

Страница 24: ...r off 1 AccesstheLOCSWsubmenu When is released the LOCSW sub menu is displayed 2 To access one or more menus press to select the calibration menu CAL is displayed NOTE NOTE NOTE NOTE NOTE Pressing cha...

Страница 25: ...steps 3 and 4 OFF OFF OFF OFF OFF MODE MODE MODE MODE MODE ON ON ON ON ON TARE TARE TARE TARE TARE ON ON ON ON ON TARE TARE TARE TARE TARE MENU LOCK OUT PROTECTION MENU LOCK OUT PROTECTION MENU LOCK...

Страница 26: ...gs not properly set up Cable connections Microprocessor lock up Lock set ON Vibration on table surface SYMPTOM Unit will not turn on Incorrect weight reading Unable to store menu settings changes RS23...

Страница 27: ...S232 buffer is full if installed May occur if no printer or computer is connected to the interface To clear buffer turn balance off or enter Print menu and select END 4 5 Function is disabled by the L...

Страница 28: ...onent or in rare cases a severe static charge If error persists balance must be serviced 9 8 Hardware error causing invalid calibration data checksum Balance may need recalibration particularly linear...

Страница 29: ...7 0 001 0 007 0 01 0 07 0 01 0 07 Std dev g Linearity g 0 001 0 002 0 01 0 001 0 01 0 02 0 1 0 01 0 1 Tare range Full capacity by subtraction Stabilization time 2 5 seconds Sensitivity drift 10 30 C 1...

Страница 30: ...ase accessories please call Ohaus Corporation toll free at 800 526 0659 an Ohaus Product Parts Specialist will be available to help you ACCESSORIES ACCESSORIES ACCESSORIES ACCESSORIES ACCESSORIES OHAU...

Страница 31: ...pply if the product has been damaged by accident or misuse exposed to radioactive or corrosive materials has foreign material penetrating to the inside of the product or as a result of service or modi...

Страница 32: ...oad ENGLAND Florham Park NJ 07932 USA Tel 44 0 1954 251343 Tel 973 377 9000 Fax 44 0 1954 250205 Fax 973 593 0359 With offices in Germany France Spain Italy Poland Canada Mexico and Japan P N 77331 05...

Отзывы: