Specific Gravity determinations are easily made on the
balance.  Swing the pan support and pan out of the way.
Raise the specific gravity platform to the desired position
by grasping the round end.  Release platform at desired
elevation and it will lock in that position.

SPECIFIC GRAVITY DETERMINATIONS (C

SPECIFIC GRAVITY DETERMINATIONS (C

SPECIFIC GRAVITY DETERMINATIONS (C

SPECIFIC GRAVITY DETERMINATIONS (C

SPECIFIC GRAVITY DETERMINATIONS (Cont

ont

ont

ont

ont.)

.)

.)

.)

.)

                      Figure 9. Example of 183.6 Gram Reading

Figure 10.

READING THE VERNIER - Model 310

READING THE VERNIER - Model 310

READING THE VERNIER - Model 310

READING THE VERNIER - Model 310

READING THE VERNIER - Model 310

Each graduation on the dial has a value of 0.1 gram.  A vernier adjacant to the dial
breaks down these values in 0.01 gram increments.  To read the vernier, read the
nearest gram value to the right of the zero vernier graduation.  Add to that the vernier
graduation value at the vernier line which most closely lines up with any of the other
dial graduations.  Figure 8 indicates a reading of 6.74 grams.

Figure 8. Vernier Dial Reading of 6.74 Grams.

6.70 gram Graduation

Zero Vernier Graduation

0.04 gram Vernier Graduation

Dial

Vernier

Model 311

Model 311

Model 311

Model 311

Model 311

1.

Working from the rear beam forward, move the 200 gram poise on the rear beam
to the first notch which causes the pointer to drop, then move it back one notch,
causing the pointer to rise

2.

Repeat this procedure with the 100 gram poise.

3.

Repeat this procedure with the 10 gram poise.

4.

Slide the 1 gram poise to the position which brings the pointer to zero.  The weight
of the specimen is the sum of values of all poise positions, read directly from the
graduated beams.  See Figure 9.

NOTE: With a little practice, you will become proficient in learning exactly how fast to
turn the dial to come exactly to balance position the first time.

Shortcut procedures may be used in instances where approximate weight of the
specimen is known, as follows:

For specimens less than 100 grams, omit step 1.
For specimens less than 10 grams, omit steps 1and 2.
For specimens less than 1 gram, omit steps 1, 2 and 3.

Содержание CENT-O-GRAM 311

Страница 1: ...tion Manual DIAL O GRAM BALANCE Model 310 and CENT O GRAM BALANCE Model 311 Ohaus Corporation Ohaus Corporation Ohaus Corporation Ohaus Corporation Ohaus Corporation 29 Hanover Road Florham Park NJ 07...

Страница 2: ...ustment Zeroing is easily and quickly achieved by means of a counter balancing knob at the end of the beam The balances are intended for use in education and industry applications They produce quick r...

Страница 3: ...e and specific gravity stand Hold the base upside down Insert the round flat end of the stand through the slot in the base Rotate stand into position as shown in Figure 4 It will turn easily if you ro...

Страница 4: ...eaded rod into the recessed area of the base Tighten the nut securely with the throw away wrench 7 Turn the balance over If the specific gravity stand is not already nested in the base lift the round...

Страница 5: ...Place the specimen on the pan of the balance Proceed as follows for the fastest method of weight determination Model 310 Model 310 Model 310 Model 310 Model 310 1 Move the 200 gram poise on the rear...

Страница 6: ...y lines up with any of the other dial graduations Figure 8 indicates a reading of 6 74 grams Figure 8 Vernier Dial Reading of 6 74 Grams 6 70 gram Graduation Zero Vernier Graduation 0 04 gram Vernier...

Страница 7: ...he magnet face The tape will pick up foreign material and prevent it from interfering with movement of the damper vane The specimen can then be suspended from a fine wire or thread from the lower hook...

Страница 8: ...This warranty does not apply if the product has been damaged by accident or misuse exposed to radioactive or corrosive materials has foreign material penetrating to the inside of the product or as a...

Отзывы: