background image

1

INSTALLATION
Selecting the Location

The balance should be used indoors only and in an environ-
ment which is free from excessive air currents, corrosives,
vibration, and temperature or humidity extremes (Max 85 %).
Maximum altitude not to exceed 4000 m above sea level.
These factors will affect displayed weight readings.

DO NOT install the balance:

• Next to open windows or doors causing drafts or rapid

temperature changes.

• Near air conditioning or heater vents.

• Near vibrating, rotating or reciprocating equipment.

• Near magnetic fields or equipment that generates mag

netic fields.

• On an unlevel or unstable work surface.

NOTE: Manufacturer cannot guarantee the safety of the
product if it is not used according to the instructions.

Setting Up and Leveling the Balance

Exact horizontal positioning and stable installation are pre-
requisites for repeatable results. To compensate for small
irregularites or inclinations at the location, the instrument can
be leveled.

For exact horizontal positioning, the balance is equipped with
a level indicator and two leveling feet located at the rear of
the balance.

Position the balance in the intended operating location.  Adjust
the leveling feet at the rear of the balance until the air bubble
in the indicator is centered.

NOTE: The instrument should be leveled each time its loca-
tion is changed.

M o

de

Off

 On

On

Prin

t

INTRODUCTION

This manual covers installation, operation and troubleshoot-
ing for the OHAUS

®

 Adventurer

TM 

Balances. To ensure proper

operation of your balance, please read this manual completely.

DESCRIPTION

The Ohaus Adventurer

TM 

balances are precision weighing in-

struments, designed to provide years of service with virtually
no maintenance. Ten models are available with capacities from
65 g to 4100 g. The 65 g through 310 g balances include a
draft shield. Weigh below operation is made possible with a
built-in weigh below hook.

The Adventurer

TM

 balances are constructed with a durable

housing, leveling feet, built-in leveling bubble, and a large
custom LCD. Control buttons are clearly marked as to their
function, with large Tare buttons located on either side of the
front panel.

All Adventurer

TM

 balances are initially factory set to measure

in grams and can be set to measure in *kilograms, milligrams,
carats, Newtons, pounds, ounces, troy ounces, grains, pen-
nyweight, mommes, mesghals, Hong Kong Taels, Singapore
Taels, Taiwan Taels,  Ticals, and Parts Counting. Simple three
button operation allows for the selection of measuring units,
calibration and printing parameters. A standard RS232 inter-
face permits communication to an external printer or com-
puter.
*See specifications for measuring units which are available.

Power is supplied through an AC adapter. Accessories include:
an in-use cover, security device, calibration masses, printer,
and scoops. See accessory section.

Behind your instrument stands OHAUS Corporation, a leading
manufacturer of precision weighing equipment. An Aftermarket
Department with trained instrument technicians is dedicated
to provide you with the fastest service possible in the event
your instrument requires servicing. OHAUS Corporation also
has a Customer Service Department to answer any inquiries
regarding applications and accessories.

MENUS

Adventurer

TM

 balances  contain four display menus which en-

able you to select measuring units, calibrate the balance, turn
on a tone signal which operates with each key stroke, and set
up communication/print parameters.

• UNITS Menu - Allows up to 16 measuring units to be se

lected plus parts counting.

• LIN Calibration Menu - Allows the balance to be calibrated

by using linearity calibration methods. Two masses are
required.

• SYS Menu - Enables tone signal with each keystroke.

• PRINT Menu - Allows communication parameters to be

set which include Baud rate, Parity, Data and Stop bits. A
Reset function permits returning the communication pa
rameters to factory settings.

• MENU END - When selected, balance returns to weigh

mode.

BUBBLE LEVEL

LEVELING FEET (2)

UNPACKING

All Adventurer

TM

 balances are supplied with a weighing plat-

form, AC power adapter, built-in weigh below hook, instruction
manual and warranty card. Draft shields are supplied with
65 g through 310 g balances.

Carefully unpack all items.

• Check the instrument for transport damage.

Immediately inform your Ohaus dealer if you have
complaints or if parts are missing.

• Store all parts of the packaging. This packaging guaran-

tees the best possible protection for the transport of your
instrument.

Содержание Adventurer series

Страница 1: ...i INSTRUCTION MANUAL AdventurerTM Balances M ode Off On On Print Mode Off On On Print...

Страница 2: ...EC EN55011 1991 class B Radiointerferenze Compatibilit elettromagnetica EN50082 2 1995 Immunit ISO 9001 Registration for Ohaus Corporation Ohaus Corporation USA was examined and evaluated in 1994 by t...

Страница 3: ...UNG VERWENDET WIRD KANN DER FUNKVERKEHR GEST RT WERDEN DURCH DEN BETRIEB DIESES GER TS IN EINEM WOHNGEBIET K NNEN DERARTIGE ST RUNGEN VERURSACHT WERDEN IST DIES DER FALL MUSS DER BENUTZER DIESE ST RUN...

Страница 4: ...anel All AdventurerTM balances are initially factory set to measure in grams and can be set to measure in kilograms milligrams carats Newtons pounds ounces troy ounces grains pen nyweight mommes mesgh...

Страница 5: ...setup procedure 2 If it is necessary to rezero the display momentarily press O T 3 Place item s to be weighed on the pan and read the weight on the display The stability indicator appears when the re...

Страница 6: ...utomatic stable read ings is OFF Only one of these may be set on at a time Stable Data On or Off When STBL ON is displayed press Mode Off to select ON or OFF then press O T AUTO OFF is displayed Auto...

Страница 7: ...then the weight of the mass on the pan is displayed 5 Remove the calibration mass from the pan The balance is now calibrated and returns to the weighing mode Linearity Calibration 1 With the balance O...

Страница 8: ...listed codes and follow instructions to correct the problem Err 2 0 Stability error Check if balance is located near vibrating equipment or if air currents are affecting it Err 3 0 Calibration error...

Страница 9: ...oston Road Boite Postale 30 An der Johanneskirche 6 Motores 178 Beaumont Leys 85 rue Joseph Bertrand D 35390 Giessen 08038 Barcelona Leicester LE4 1AW 78220 Viroflay Deutschland Espana England France...

Отзывы: