background image

EN-2 

Explorer

®

 Balance Ethernet Option Interface Kit

 

 

 

2. INSTALLATION 

 

2.1 Safety Precautions

  

For safe and dependable operation of this equipment, please comply with 
all safety precautions mentioned in this manual. 

 

Note: 

Disconnect the equipment from the mains power supply before 

beginning installation. 

 

CAUTION: 

 

The electronics of the Option are very sensitive to electrostatic discharges. In 
order to protect the components, necessary measures must be taken when the 

Option is installed so as to provide protection against electrostatic discharges. 

2.2 Installation procedure 

Please note the following: 

The interface is installed into the Display and is powered by the Base. 

 
Follow the steps below. Refer to the Figures when performing these steps. 

 

 

 

Make sure Balance is unplugged 
(turned OFF) 
 
 
 

 

 

Detach the Display:  
press buttons on both sides to 
disconnect. Then pull Display away 
from base. 

Содержание 83021082

Страница 1: ...Explorer Balance Ethernet Interface Option Kit Installation Instructions...

Страница 2: ......

Страница 3: ...ase read this manual completely before installation and operation CAUTION READ ALL SAFETY WARNINGS BEFORE INSTALLING MAKING CONNECTIONS OR SERVICING FAILURE TO COMPLY WITH THESE WARNINGS COULD RESULT...

Страница 4: ...very sensitive to electrostatic discharges In order to protect the components necessary measures must be taken when the Option is installed so as to provide protection against electrostatic discharge...

Страница 5: ...n enlarged in photo then lift Display until it disengages 4 Unplug Display Communication Cable if desired for greater freedom of movement 5 To release the clip that secures the Display Communication C...

Страница 6: ...te Do not touch any items inside the Display 7 Install the new Ethernet interface board into the Display Take care to seat the device properly in the slot Push interface board into the Display securel...

Страница 7: ...r the release button either side as shown here 12 Re wind any unused cable First remove the Platform Sub Platform or Wind Ring and Wind Shield if present Then turn base over to rewind cable around cab...

Страница 8: ...a Local Area Network After successful installation of the Ethernet Interface Option the Ethernet appears as an option on the Communication Menu Press Ethernet to see options for Device Settings and Pr...

Страница 9: ...rer Balance Ethernet Option Interface Kit EN 7 The Port setting cannot be changed Press IP Address to change the setting Press Default Gateway to change the setting Press Subnet Mask to change the set...

Страница 10: ...NANCE 4 1 SERVICE INFORMATION For Service assistance in the United States call toll free 1 800 526 0659 between 8 00 AM and 5 00 PM Eastern Standard Time An Ohaus Product Service Specialist will be av...

Страница 11: ......

Страница 12: ...oration 7 Campus Drive Suite 310 Parsippany NJ 07054 USA Tel 973 377 9000 Fax 973 593 0359 With offices worldwide www ohaus com 83021183 P N 83021183A 2016 Ohaus Corporation all rights reserved Printe...

Отзывы: