Страница 2: ...2 12 10 OHAUS Operator Manual Aviator 5000 Order number 72246393...

Страница 3: ...ng with PLUs 11 3 3 Using tare 13 3 4 Zeroing 14 3 5 By count operation 14 3 6 Accumulating 15 3 7 Change function 16 3 8 Fix unit price and or tare 17 3 9 Hold function 18 3 10 Weighing with 100 g 1...

Страница 4: ...elling while maintain ing the highest accuracy 1 2 Device overview 1 2 1 Keyboard The keyboard is divided into four sections The advanced function keys depend on the region 1 2a 3 2b 2c 4 1 PLU preset...

Страница 5: ...PLU NET Net value gross minus tare push button tare exists FIX Unit price and or tare is fixed X Scale is in by count mode 100 g 100 g pricing is activated 1 2 1 2 lb pricing is activated 1 4 1 4 lb p...

Страница 6: ...tures on the underside 2 3 4 5 The following connections are located on the underside of the scale 1 Adjustable feet 2 Grips 3 Power supply connection 4 Power supply storage box 5 Calibration button O...

Страница 7: ...calibrated have a label indicating this on the packaging Scales with a green M on the type plate are ready for operation Scales which are calibrated in two stages have a label indicating this on the...

Страница 8: ...ocks and vibrations No excessive temperature fluctuations No direct sunlight No strong drafts Select a stable vibration free and preferably horizontal location for your scale 2 3 Setting up the scale...

Страница 9: ...minal end to the positive pole red or and the black terminal end to the negative pole black or 6 Close the battery compartment 7 Put the weighing pan back on The battery life is affected by charging a...

Страница 10: ...a short display test All segments and status messages briefly light up the software version is displayed The scale is ready when the weight display appears 2 7 Cleaning CAUTION Damage to the scale Tu...

Страница 11: ...Creating a PLU 1 Enter the unit price price kg 2 Press and hold the PLU key until a long beep can be heard P appears in the weight display 3 Enter the PLU number between 1 and 9999 4 Wait until the s...

Страница 12: ...perator setup Step 7 ON 1 Place the item on the scale 2 Enter the corresponding PLU number The PLU is called up automatically Unit price and price to pay are displayed 3 Remove the item from the scale...

Страница 13: ...your containers you can enter the tare weight via keyboard So you do not have to tare the empty container Taring an empty container 1 Place the empty container on the scale 2 Press the Tare key The we...

Страница 14: ...kg In such cases the scale must be reset to zero The maximum allowed deviation to be compensated by zeroing is 2 of the weighing range Press the Zero key The weight display is set to zero 3 5 By coun...

Страница 15: ...on is ended Use the C key to leave by count operation 3 6 Accumulating This functionality is only legal in certain regions 1 Place the first item on the scale 2 Carry out pricing as described above 3...

Страница 16: ...change is displayed 4 Press the C key to return to normal weighing mode Multiple items 1 Carry out accumulating as described above 2 When the total is displayed press the Change key The total price t...

Страница 17: ...ample on the scale 3 Carry out pricing as described above 4 Press the FIX key When removing the item from the scale the unit price and tare are still displayed 5 Place the next sample on the scale The...

Страница 18: ...key again until a long beep can be heard 3 10 Weighing with 100 g 1 2 lb 1 4 lb price unit For many products customers are used to a price per 100 g 1 2 lb 1 4 lb This function is only available if pe...

Страница 19: ...on is only available if permitted by the national W M regulations 1 Carry out pricing as described above 2 Press the EUR key The price to pay is displayed in the second currency 3 Press the EUR key ag...

Страница 20: ...urrent setting of the step is displayed Changing settings To toggle between the settings of a setup step use the Enter On Off key When moving to another setup step the selected setting is con firmed 4...

Страница 21: ...in bold print No Setting Description 1 Reset ON Reset operator setup functions to factory settings OFF Do not reset operator setup functions 2 Beeper ON Beep when a key is pressed OFF No sound when a...

Страница 22: ...ery charging function disabled To change charging function you are asked to enter a passwort 55555 10 Function keys 0 Function keys disabled 1 Function keys enabled 11 PLU ON Storing PLUs enabled OFF...

Страница 23: ...splayed refer to the error message list Error message list Error Cause Remedy E11 RAM error Call service technician E16 ROM error Call service technician E18 EEPROM error Call service technician E34 P...

Страница 24: ...Operating temperature 10 C to 40 C Storage temperature 25 C to 50 C Electrical data Power supply 12 V DC Power consumption 50 mA Plug in adapter In 230 V AC 50 Hz Out 12 V DC 800 mA Charging current...

Страница 25: ...electrical and electronic equipment Should you have any questions please contact the corresponding authorities or the dealer from whom this device was purchased If this device is passed on for example...

Страница 26: ...26 12 10 OHAUS Operator Manual Aviator 5000 Order number 72246393...

Страница 27: ...27 12 10 OHAUS Operator Manual Aviator 5000 Order number 72246393...

Страница 28: ...Subject to technical changes 12 2010 Ohaus Corporation Printed in Switzerland Order number 72246393 www ohaus com...