Conversion console display in Metric(km) or English(ml)
Switch the power on, press and hold
START
button and hold them, then pull up the
safety key, console will display “KM” or “ML”, use
START
button to select between
“KM” and “ML”, then press
STOP/ENTER
to confirm and return power on status.
Enter the service Engineer Mode
Switch the power on, press and hold
INCLINE UP
and
DONW
and
STOP/ENTER
3
buttons and hold them, then pull up the safety key to enter the ENGINEER MODE.
Time/Distance display shows “
1
” and blinking.
Set and display the manufacture date and software version
Press START button, Time/Distance display shows the manufacture YEAR, Heart
Rate display shows manufacture MONTH, Calories display shows manufacture DATE.
Speed display shows software version. The service engineer can adjust the
manufacture date by pressing Incline Up and Down button follow the blinking display
then press
STOP/ENTER
button after each adjustment to record the service date if
necessary. After all the adjustment done, press
STOP/ENTER
button again to exit the
Engineer Mode.
Incline Calibration
Enter Engineer mode.
Press
INCLINE UP
and
DOWN
button to select computer display shows “
2
” then
press
START
button to enter the Incline Calibration Procedure.
Incline Level display shows “0”. Press
INCLINE UP
and
DOWN
button to bring the
deck to horizontal position then press
STOP/ENTER
button to set the L0 level.
After set the L0 level, Incline Level display shows “12” and the treadmill will
automatically incline up. Waiting for treadmill incline stop, press
INCLINE UP
and
DOWN
button to adjust incline L12 correct position , then press
STOP/ENTER
twice
to set the L12 level and exit the engineer mode.
Engineer mode Setting
200mm
380mm
Incline level 1 position
Incline level 12 position
Содержание ACTIVO TREK PRO T8-1
Страница 1: ...SERVICE MANUAL FOR RUN 4 1 IWM MP AP Ogawa ACTIVO_TREKPRO_T8 1 ...
Страница 12: ...506 503 503 505 817 817 504 504 501 835 507 835 848 507 507 502 ...
Страница 14: ...Wire Diagram ...
Страница 15: ......