4 of 10
Drawing showing panel cut out. Please also see dimensional drawing in section 6.
2.3 CONNECTING THE DUAL ENGINE DISPLAY
Before making any connections to the unit, ensure the NMEA2000 bus power and DC supply are
turned off.
Connect NMEA2000 cable to ‘Socket’ on the back of the unit, observing correct orientation
to ensure the keyway aligns. The cable can be extended up to 6mtrs and connect into the
T-adapter on the network backbone. Ensure that the screw ring is securely tightened so that
the connection remains sound. Connect the two J1939 cables in the same manner. Ethernet
connector is for internal Offshore programming use ONLY. The DC Power cable can be inserted
into the port marked. Ensure correct orientation and make sure the screw ring is securely
tightened. There are two USB A and one USB OTG connectors, these are not for customer
use and are intended for future Offshore Systems usage. Connect the Control Panel D Type
Connector to the 9Way Switch Control Panel.
502
19.8
120.
3
4.
7