background image

9 of 13

Electrical and Mechanical

Environmental

Description

Comment

Operating Voltage

9 to 32 Volts

Power Consumption

45mA 

Average Operating

Load Equivalence Number

LEN

Reverse Battery Protection Yes

Indefinitely

Load Dump Protection

Yes

SAE J1113

Size

120x135x35

mm

Weight

230 

gram

Mounting

Panel mounted

Parameter

Value

IEC 60954 Classification

Protected

Degree of Protection

IP65

Operating Temperature

-25°C to 50°C

Storage Temperature

-40°C to 70°C

Relative Humidity

93%RH @40° per IEC60945-8.2

Vibration

2-13.2Hz @ ±1mm, 13.2-100Hz @ 7m/s2 per IEC 60945-8.7

Electromagnetic Emission

Conducted and Radiated Emission per IEC 60945-9

Electromagnetic Immunity

Conducted, Radiated, Supply, and ESD per IEC 60945-10

Safety Precautions

Dangerous Voltage, Electromagnetic Radio Frequency per 

IEC 60945-12

Содержание 5801

Страница 1: ...V BENNETT TRIM TAB ADAPTOR WITH NMEA2000 CAN BUS AND RS485 RTU MODBUS INTERFACES PART NUMBERS 5801 USER MANUAL Revision 1 0 1...

Страница 2: ......

Страница 3: ...2 1 2 Product Features 2 2 Installation 3 2 1 Unpacking the box 3 2 2 Mounting the unit 3 2 3 Connecting the Deutsch Plug 4 2 4 Unit Switch Settings 5 3 Calibration 6 4 Maintenance 7 5 Technical Speci...

Страница 4: ...o achieve the best results 1 1 FIRMWARE REVISION The information in this manual corresponds to firmware revision 1 1 4 1 2 PRODUCT FEATURES The Offshore Dynamics 5801 Bennett Trim Tab Adaptor has the...

Страница 5: ...he following items in the 5801 shipping box 1 x 5801 Bennett Trim Tab Adaptor 1 x 5801 User Manual This document 3 x 5801 R Trim Tab Remote 2 2 MOUNTING THE UNIT The unit should be mounted to a flat s...

Страница 6: ...UTSCH PLUG The unit is connected to the sensors and the communications interfaces via the 12 way Deutsch plug according to the following connection table Pin Number Connection 1 Modbus B 2 Modbus A 3...

Страница 7: ...and 1 stop bit Please refer to Modbus specification for further information Modbus Commands The 5801 Trim Tab Adaptor identifies as slave 48 0x30 and supports one command 0x3 Read Holding Registers An...

Страница 8: ...Power up the device Press the calibrate button so that the white calibration LED illuminates Actuate each sender between it s highest and lowest positions so the 5801 can learn where these limits are...

Страница 9: ...they may remove paint or markings or may corrode the enclosure or seals Ensure that the unit is secure using the mounting holes on the device and cannot be moved relative to the mounting surface Chec...

Страница 10: ...cations NMEA2000 Parameter Group Numbers PGNs Modbus RS885 RTU Memory Locations Parameter Comment Accuracy 2 No of Inductive sensors Up to 3 Type PGN No PGN Name Monitor PGN130576 Trim Tab Status Prot...

Страница 11: ...anel mounted Parameter Value IEC 60954 Classification Protected Degree of Protection IP65 Operating Temperature 25 C to 50 C Storage Temperature 40 C to 70 C Relative Humidity 93 RH 40 per IEC60945 8...

Страница 12: ...ew Milton Hampshire BH25 6RH United Kingdom Tel 44 0 1425 610022 Fax 44 0 1425 614794 Email sales osukl com Web www osukl com Copyright 2016 Offshore Dynamics Ltd All rights reserved Our policy is one...

Страница 13: ...SEQUENTIAL DAMAGES DAMAGES FOR LOSS OF USE LOSS OF ANTICIPATED PROFITS OR SAVINGS OR ANY OTHER LOSS INCURRED BECAUSE OF INTERRUPTION OF SERVICE IN NO EVENT SHALL OFFSHORE DYNAMICS AGGREGATE LIABILITY...

Страница 14: ...12 of 13 OFFSHORE DYNAMICS PRODUCT MAP 8...

Отзывы: