![Offshore 3345 NMEA2000 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/offshore/3345-nmea2000/3345-nmea2000_user-manual_3457737010.webp)
8 of 30
unit is delivered each battery or DC source has a generic name that can be set to any
name the user wishes to help identify the Battery or DC source. See section 4.2.4 later in
this manual for information on how to do this.
2. At the top left hand side of each side there is a Battery or DC Source Instance number
which needs to correspond with the Instance of the DC Monitor supplying the data to the
network.
3. The top display gauge is the current charging or being drawn from the battery / DC
source. This gauge scale has our “Autoranging” feature so that if the current exceeds 60
amps the gauge scales will automatically autorange to a higher scale. This gauge also
includes a digital display panel showing the current flow numerically.
4. The second display gauge shows the voltage of the battery or DC source, also with
autoranging between 12 and 24 volt systems and a digital display panel.
5. At the bottom of each side is a battery temperature gauge.
3.4 GENERATOR / AC SOURCE SUPPLY
By pressing the “ACPWR” button the display will show information about the first two AC
Generators or AC Busses or Shore Power as shown below.
Repeated pressing of the “ACPWR” button will display the next two AC sources to a total of 16
sources.
Each side of the display contains the following information:
1. In the top centre of each side is the AC Source user assignable name. When the unit is
delivered each AC source has a generic name that can be set to any name the user wishes
to help identify the AC source. See section 4.2.5 later in this manual for information on
how to do this.
2. At the top left hand side of each side there is an AC Source Instance
number which needs to correspond with the Instance of the AC Monitor supplying the data
to the network.
3. The top display gauge is the current being drawn from the AC source. This gauge also
includes a digital display panel showing the current flow numerically.
4. The second display gauge shows the voltage of the AC source, also with autoranging
between 110 and 240 volt systems, and a digital display panel.
5. At the bottom of each side is an AC Source frequency gauge.