1.1 General health and safety instructions 

 

A.

 

Avoidance of danger for persons and property 

• 

Only use unit for intended purpose. 

• 

No additional mountings and modifications on the unit without our approval. 

• 

Adhere to the standards for prevention of accidents and to the plant specific safety regulations. 

• 

Read and observe installation and operating instructions. 

 

B.

 

Application limits 

 
Only use this unit according to these operating instructions and to the parameters agreed upon in the delivery contract 
(see identification plate) including the agreed operating conditions. 
 

C.

 

Avoidance of danger and damages 

 
• 

Distribute these mounting and operating instructions to appropriate department “arrival of goods, works transport, 
mounting, commissioning and maintenance”. 

• 

When passing the unit to a third party, these mounting and operating instructions must be enclosed in the national 
language of this third party. 

• 

Only skilled and qualified personnel with special work order may work on the unit, which must be free of pipeline 
stress! 

• 

Carefully read, observe and preserve these mounting and operating instructions. 

• 

Observe and adhere to the precautions marked in bold characters in the sections of these mounting and operating 
instructions! 

• 

Avoid shocks and impacts during transport, which could damage the unit. 

• 

In case of intermediate storage take care for a dry and appropriate place where the unit cannot be damaged. 

 
 

Attention 

 
The fitting is under pressure during operation! 
If flange connections, screw plugs or stuffing boxes are unfixed, hot water and steam will escape. 
 
Carry out assembly and maintenance works only if plant is completely depressurized! 
 
The fitting is hot during operation! 
Severe burns on hands and arms are possible. 
Wait until the unit has cooled before carrying out assembly and maintenance works! 
 
Severe burns and scaldings on the whole body are possible! 
 
Wait until the unit has cooled. In case of opening and disassembling the unit, residual medium can escape. Further 
evaporation is also possible on depressurized plant. 
 
Sharp-edged interior parts can cause cutting damages on the hands! 
 

2.1 Intended use 

 
The illuminators are used in direct water level gauge which can be mounted on steam generators. In the sight opening, 
the water space is indicated in green and the steam space in red. 
The level gauge works on the principle of communicating pipes. With the LL RGx illuminators, red and green light falls 
on the display unit. If there is water in the display area, then the light rays will be diverted in such a way that the green 
light beam falls on to the slit diaphragm of the display box. In the steam area the light rays are not diverted and the red 
light beam is projected. 

Содержание LL RG4

Страница 1: ...9 035 4530211 Fax 39 035 570546 www officineorobiche i t e mail info officineorobiche it GEN 2020 Information subject to change without prior notice IST 192 I 1 1 General health and safety instruction...

Страница 2: ...recautions marked in bold characters in the sections of these mounting and operating instructions Avoid shocks and impacts during transport which could damage the unit In case of intermediate storage...

Страница 3: ...iche it GEN 2020 Information subject to change without prior notice IST 192 I As a result the water compartment always appears green and the steam compartment red 3 1 Scope of supply The LL RGx illumi...

Страница 4: ...035 570546 www officineorobiche it e mail info officineorobiche it GEN 2020 Information subject to change without prior notice IST 192 I Part 1 Illuminator with round connector Illuminator with cable...

Страница 5: ...e 3 2 System description ILLUMINATOR The illuminator is modular and has two different sizes six pixels three green and three red and four pixels two green and two red Pitch between pixels is related t...

Страница 6: ...land LL RG4 CG 4W Six pixels with cable gland LL RG6 CG 6W The complete illuminator will be fixed to the steel cabinet with four screws position of one respect to another is fixed in order to maintain...

Страница 7: ...e illuminators cable length has to be defined in the order description 4 1 MOUNTING Mounting of the complete illuminator device is simply 1 Fix the LL RGx to steel plate as per the picture below 2 Fix...

Страница 8: ...obiche it e mail info officineorobiche it GEN 2020 Information subject to change without prior notice IST 192 I 4 5 Fix the last steel plate to close the enclosure always using M5 screws connect all t...

Страница 9: ...country regulation 6 1 Identification plate Marking The following data are indicated on the identification plate marking depending on the realization A Model code B Manufacturer Logo 7 1 Maintenance I...

Страница 10: ...implying return of goods within the limit specified above OFFICINE OROBICHE will replace shipment fees not included all damaged parts free provided that the failure does not ensue from incorrect use O...

Отзывы: