background image

Officine Gullo

16

WHAT TO DO IN THE EVENT OF A BREAKDOWN

Turn off the gas tap and notify the after sales service.

PROCEDURE TO FOLLOW IF THE APPLIANCE IS NOT GOING TO BE USED FOR SOME TIME

Turn off the gas tap and clean the appliance as specified above.

MAINTENANCE (only for qualified personnel)

Any kind of maintenance must only be done by qualified personnel. Before carrying out maintenance,remove the 

plug or switch off the switch above the appliance.

17

Officine Gullo

INSTRUCTIONS FOR DISCHARGING GAS EMISSIONS

Type “A” Appliances (See data plate)

Type “A” appliances must discharge the products of combustion into extractor hoods or similar devices connected to 

and efficient chimney, or directly outside. 

(Natural Discharge) Fig.1.

If there is no hood, as an alternative, an air extractor connected directly to the outside is acceptable, (Forced 

Discharge) Fig.2, but its capacity must not be inferior to what is established in item 4.3 of the UNI-CIG norm 8723.

In the event of forced discharge

The gas supply to the appliance, must be directly interlocked to the system and cut off automatically if its capacity 

drops below the values prescribed by item 4.3 of the UNI-CIG norm 8723.

Supplying the appliance with gas again must only be possible manually.

NATURAL DISCHARGE                              FORCED DISCHARGE 

 

1. Extractor hood

1. Extractor hood

2. Interlocking

Fig.1

Fig.2

Содержание GEFS8P

Страница 1: ...GEFS8P RANGE WITH OVEN FOR RESIDENTIAL AND PROFESSIONAL USE INSTRUCTIONS FOR INSTALLATION AND USE...

Страница 2: ...le the appliance s maximum power consumption The use of adapters multiple power boards and extension cords is not recommended 8 When not in use switch off the general power supply to the appliance and...

Страница 3: ...L DATA TABLE 12 RULES FOR CONVERTING AND INSTALLING OTHER TYPES OF GAS 13 CHANGING THE OPEN RING NOZZLES 13 CHECKING FUNCTIONING 13 MAINTENANCE 13 SPARE PARTS 13 USER MANUAL INSTRUCTIONS FOR USE 14 LI...

Страница 4: ...g A 1 GEFS8P 70 cm 73 cm 67 cm 97 cm 90 cm 80 cm 20 cm 3 cm 4 cm 62 cm E 42 cm 10 cm G 1 2 G 1 2 10 cm 40 cm E 80 cm 70 cm Su richiesta accensione con fiamma pilota Also available with pilot flame E L...

Страница 5: ...ackofen Bypass By pass four Oven by pass By pass horno FIG F PC GP CF GP FUOCHI FLAMME FEUX COOKING RINGS FUEGOS 562047300M00P00 1 2 3 4 1 Iniettore fuochi Einspritzventil flamme Injecteur feux Inject...

Страница 6: ...Officine Gullo 6 ELECTRICAL SCHEME TOP 1 Electrical connection 2 Push button starting burner 3 4 Power station starting burner Fig D...

Страница 7: ...AM FAN OVEN 1 Commutator 2 Capacitor 3 Power supply terminal 4 Terminal board switching 5 Engine 6 Element 7 White light 8 Green light 9 Safety thermostat 10 Thermostat Fig I z H 0 6 0 5 N 3 c a V 0 0...

Страница 8: ...rticularly concerning room ventilation and discharging gas emissions N B The manufacturer declines any responsibility for direct or indirect damage caused by improper or incorrect installation alterat...

Страница 9: ...ion of fire and panic Connection and installation of appliance ventilation and exhaust removal systems shall be done according to the Manufacturer s instructions and by qualified technicians and accor...

Страница 10: ...is supplied without the connection cable to install it proceed in the following way Remove the back panel Push the connection cable through the cable channel connect the conductor wires to the corresp...

Страница 11: ...pressure and verify that the description of the nozzle installed corresponds to the one supplied by the manufacturer Connection with natural gas H G20 The connection pressure for natural gas is 20 mb...

Страница 12: ...ner injector 1 100 mm Min output adjustment 1 100 mm Consumption Primary air h mm 135 75 kg h 0 591 20 135 75 kg h 0 582 20 205 adjustable m3 st h 0 794 20 Burner max 3 5 kW min 1 15 kW G110 8 mbar G1...

Страница 13: ...ight or left until the thermal power reaches 1 15 kW for the 3 5 kW burner 1 55 for the 5 5 kW burner and 2 5 kW for the 7 kW burner Warning If liquid gas is being used the minimum adjustment screw mu...

Страница 14: ...few seconds and then released The flame may go out in which case it is necessary to repeat the procedure By turning to the position the burner is brought to the minimum To put out the burner turn the...

Страница 15: ...re until the desired effect is achieved The brass details should then be dried Do not use polish as this is suitable for maintaining the gloss but not the antique finish and could result in an effect...

Страница 16: ...FOLLOW IF THE APPLIANCE IS NOT GOING TO BE USED FOR SOME TIME Turn off the gas tap and clean the appliance as specified above MAINTENANCE only for qualified personnel Any kind of maintenance must onl...

Страница 17: ...ctly to the outside is acceptable Forced Discharge Fig 2 but its capacity must not be inferior to what is established in item 4 3 of the UNI CIG norm 8723 In the event of forced discharge The gas supp...

Страница 18: ...me in the oven we suggest opting for the lower value in the thermostat adjustment range given in the table Cooking time will be longer if the heat is lower TYPE OF FOOD SLOT NO from the bottom QUANTIT...

Страница 19: ...ets steaks cod hake sole 1 3 1 180 30 Mackerel turbot salmon 1 3 1 180 45 Oysters 1 3 1 180 20 Oven bakes Pasta 1 3 2 185 60 Vegetables 1 3 2 185 50 Sweet and savoury souffl s 1 3 0 75 180 50 Pizza an...

Страница 20: ...Tel 39 055 656 0324 info officinegullo com Via Della Torricella 29 Antella Bagno a Ripoli 50012 Florence Italy OFFICINEGULLO COM en international V 1 0 7 20...