11
Officine Gullo
TABLE OF BURNERS TECHINCAL DATA
F...S4G
12,68 kWh/kg
G30
BUTANE
28 mbar
12,87kWh/kg
G31
PROPANE
37 mbar
9,45 kWh/m3st.
G20
NATURAL GAS
20 mbar
Burner Injector 1/100 mm
Pilot Injector
Consumption tot.
2x87
1x19
kg/h 0,552
2x87
1x19
kg/h 0,544
2x135A
1x27
m3 st./h 0,741
F...S6G
Burner Injector 1/100 mm
Pilot Injector
Consumption tot.
3x87
2x19
kg/h 0,828
3x87
2x19
kg/h 0,816
3x135A
2x27
m3 st./h 1,111
F...S8G
Burner Injector 1/100 mm
Pilot Injector
Consumption tot.
4x87
2x19
kg/h 1,104
4x87
2x19
kg/h 1,088
4x135A
2x27
m3 st./h 1,481
SUBSTITUTING THE NOZZLE IN THE MAIN BURNER (fig.B)
•
Remove the front fixing screws from the panel (see figure B, pos. 02), remove the start up cable from the piezoelectric
ignition device (03).
•
Using a suitable spanner, unscrew the nozzle (09) and substitute it with the right one (see table of “burners” technical data).
•
The main burner does not require any regulation of the primary air.
SUBSTITUTING THE NOZZLE IN THE PILOT BURNER (fig.B)
The flame of the pilot burner has fixed air.
The only operation necessary is the substitution of the nozzle according to the type of gas.
It is therefore necessary to unscrew the screws as specified in the previous point; with a suitable spanner unscrew the fitting and
substitute the nozzle with a suitable one. With the right nozzle, the flame must lap the thermocouple.
Important!
After having effected the conversion to another type of gas, it is necessary to update the data plate, indicating the type of gas
for which the appliance has been converted.
CHECKING FUNCTIONING
•
The appliance contains the instructions necessary for use.
•
Check the appliances for gas leaks.
•
Examine the flame of the pilot burner; it must lap the thermocouple and be blue, otherwise examine the nozzle
of the pilot burner.
•
Check the lighting and flame of the main burner.
•
We urge the user to follow the instructions when using the appliance.