Officine Gullo
10
Picture 2E
There are several screws around the
perimeter of the back panel, to remove the
panel you need to remove all the screws
around the perimeter and them pull away
the panel to access the terminal block.
IMPORTANT ! MAKE SURE TO ALWAYS
DISCONNECT THE APPLIANCE FROM
THE ELECTRICITY BEFORE WORKING
ON IT.
Picture 1E
Electrical Supply.
This appliance requires electrical supply – ensure an appropriately qualified person completes the electrical
connection.
The appliance must be connected to an equipotential system. The connection screw is positioned at the back of the
appliance and is identified by the symbol
Attention!
the manufacturer cannot be held responsible for, and does not cover in the guarantee any damage
resulting from bad or faulty connections.
The appliance may be supplied without the connection cable. In this case, the connection cable must have the
following characteristics: it must be type H05RNF and must have an adequate section for the power of the appliance
(see technical data table).
To install, proceed in the following way:
-Remove the back panel bye removing the screws that are around its perimeter as shown in picture 1E;
-Fit the connection cable through the cable channel, connect the conductor wires to the corresponding terminals in
the junction box as shown in picture 2E below and fix them into place.
-Block the cable with the cable blocker, and reassemble the panel. The ground wire must be longer than the others
so that if the cable blocker should break for any reason, it will disconnect after the hot wires.
The installation of this appliance must conform with all applicable local codes. In the absence of local codes, the
installation must conform to the latest level of the National Electric Code, ANSI/NFPA 70.
11
Officine Gullo
USER MANUAL
STARTING UP
Before using the appliance, it is necessary to clean it carefully, especially the tub (see paragraph “cleaning and
care”).
Check the connection of the appliance and start it up following the instructions.
INSTRUCTIONS FOR USE
Attention!
Use the appliance only under surveillance.
- Never start up the appliance without water.
With pasta cookers it is possible to cook pasta, vegetables, rice, eggs, legumes, etc.
WATER SUPPLY CHARACTERISTICS
The system must be connected to a drinking water supply with the following Characteristics. Failure to do so
automatically
invalidates the guarantee:
Total hardness:
0,5 to 5°F to prevent the build-up of lime-scale
Pressure:
50 to 250 kPa (0,5-2,5 bar).
Chlorine ion concentration (Cl-)
: not more than 10 ppm (acceptable value) to avoid damaging the internal steel
elements
pH
: over 7
Electrical conductivity
: 50 to 2000 μS/cm (20°C)
TURNING ON
Check that the water drainage tap is closed.
1) Turn on the tap to load the tank to the desired level, which must be higher than the minimum level and do not
exceed the maximum level, which is marked on the tank by the symbol (--)
2) Switch on the main switch installed above the appliance. Turn the control knob from position “0” to the degree of
cooking desired, between 1(min) and 3 (max).
The white light shows that the heating element is working.
To turn off the appliance, turn the knob into position “O”.
EMPTYING THE TUB
To carry out this operation, it is necessary to open the outlet tap (lever in vertical position) which can only be reached
through the cabinet door situated below the appliance.