Officine Gullo CVCS4EM Скачать руководство пользователя страница 8

8

Officine Gullo 

Electrical Supply.

This  appliance  requires  electrical  supply  ensure  an  appropriately  qualified  person 

completes the electrical oven-up. The appliance must be connected to an equipotential 
system. 

The connection screw is positioned at the back of the appliance and is identified by 

the symbol 

 .

T

he appliance is supplied without the connection cable. To install the power supply 

cable, proceed as follows:

- Disconnect the power supply.
- Remove the bottom panel
- Push the connection cable through the cable blocker, connect the conductor wires 

to the corresponding terminals in the junction box and fix them into place.

- Block the cable with the cable blocker, and reassemble the bottom panel. The earth 
wire must be longer than the others so that if the cable blocker should break, it will 
disconnect after the tension wires.
The connection cable must have an adequate section for the power of the appliance 
and be resistant to a temperature of at least 150°C (see technical data table).

DIMENSIONS

 cm

POWER SUPPLY

Power 

max kW

Absorbition 

max A

Power 

supply cable

CVCS4EM

40 x 70 x 90h

230V~ 50/60 Hz

7,8

33,91 A

3 x 6 mm²

TECHNICAL ELECTRICAL DATA TABLE

Содержание CVCS4EM

Страница 1: ...x INSTRUCTIONS for installation and use PASTA COOKER FOR RESIDENTIAL AND PROFESSIONAL USE CVCS4EM ...

Страница 2: ......

Страница 3: ...TABLE OF CONTENTS WARNINGS CAUTION 4 SAFETY INSTRUCTIONS 5 ELECTRICAL SCHEME 6 INSTALLATION INTRUCTIONS 7 USE AND MAINTENANCE INSTRUCTIONS 9 CLEANING AND CARE INSTRUCTIONS 10 ...

Страница 4: ... doubt please consult a qualified electrician 5 When not in use for extended periods switch off the general power supply to the appliance and close the gas supply valve 6 Do not obstruct the appliance s cooling or heat dissipation vents 7 The appliance must be used only for the purposes for which it has been expressly designed cooking All other uses such as the heating of a room are considered ina...

Страница 5: ...A check before each use to determine that no hazardous materials are in the area is recommended 6 Children should not be left alone or unattended in the kitchen while the appliance is in use 7 This appliance should not be operated without a properly sized and operational ventilation hood 8 The ventilation and flue ways of this appliance must remain unobstructed at all times 9 Do not store items of...

Страница 6: ...DIAGRAM ESQUEMA ELECTRICO 549025300 M00_00 549021400 M00_00 230V 50 60Hz 230V 3 50 60Hz 1 2 Commutatore Schalter Commutateur Commutator Conmutador 3 Morsettiera Klemmleiste Bornier Junction box Tablero de bornes 4 Morsettiera commutazione Switching Klemmenblock Bornier de commutation Switching terminal block Tablero de bornes de conmutación 5 Resistenze Widerstände Résistances Elements Resistencia...

Страница 7: ...ICAL INSTALLATION The data plate is on the front panel see diagram in electric connection item and has all the data necessary for the connection When fitting the appliance must be levelled using a spirit level slight differences of level can be adjusted by screwing or unscrewing the adjustable feet The main switch or the socket must be near the appliance and easily accessibile It is advisable to p...

Страница 8: ...e connection cable through the cable blocker connect the conductor wires to the corresponding terminals in the junction box and fix them into place Block the cable with the cable blocker and reassemble the bottom panel The earth wire must be longer than the others so that if the cable blocker should break it will disconnect after the tension wires The connection cable must have an adequate section...

Страница 9: ... Cl not more than 10 ppm acceptable value to avoid damaging the internal steel elements pH over 7 Electrical conductivity 50 to 2000 μS cm 20 C TURNING ON Check that the water drainage tap is turned off 1 When powering the device the red light flashes briefly for about second 2 In the absence of water in the tank the red light keeps flashing 3a Turn on the tap to load the tank to the desired level...

Страница 10: ... steady red light To reset the alarm condition after removing the fault that caused the intervention broken or disconnected level probes problems with the water supply drain valve open the system must be turned OFF ON CARE AND CLEANING INSTRUCTIONS CLEANING AND MAINTENANCE Attention During cleaning do not wash the external parts of the appliance with direct sprays of water or with high pressure Af...

Страница 11: ...e chromium plated brass details in order to avoid spoiling the beauty of the chrome with an artificial patina All the chromed surfaces should be clean as needed with a warm water and mild soap and a soft cloth or micro fiber Do not use abrasive pads CLEANING SATIN FINISH NICKEL PLATED BRASS SURFACES No synthetic varnishes have been used to obtain the special nickel plating on the satin finish nick...

Страница 12: ...WWW OFFICINEGULLO COM V 2 3 11 17 OFFICINE GULLO S R L via della Torricella 29 50012 Antella Bagno a Ripoli FI Tel 39 055 6560324 621807 Fax 39 055 620670 info officinegullo com us ...

Отзывы: