7 - Final checklist

To prevent improper connections leading to damage of 
electrical components and so voiding the warranty, the 
following steps must be performed:

1. Check the electrical requirements and make sure you have 

the correct electrical supply and that the range is properly 
grounded.

2. Before the range is connected, turn on the power supply.

3. Check power at the junction box wires using a voltmeter 

having a range of 0-250 VAC. If you have installed the 
oven for use on 240 Volt supply, you should find that the 
voltage reading between the black and red wires (Line to 
Line) should be 220 to 240 Volts. If you have modified the 
range(s) for use on 208 Volt, the voltage reading between 
the black and red wires should be 190 to 208 Volts.

4  Connect the range to the power supply.

5. Set the clock by following these steps:

• Press 

TIME

 key twice until the display shows “SET TIME”.

• Immediately press 

+

 or 

-

 keys to set hours.

• Press 

TIME

 key again to change minutes.

• Immediately press 

+

 or 

-

 keys to set minutes, hold to 

change by ten (10) minutes step.

• Press 

TIME

 key or wait for a few seconds.

  Clock is now set.

6. Test the bake mode by following this step:

•  Move cooking mode knob to “BAKE” position.

•  Cooling fan, oven lights, preheat led will turn on.

•  A beep is sounded when the oven reaches the preset 

350 °F (175 °C) and the preheat light turn off.

•  Move the knob back to “OFF” position to stop cooking.

7. To check the other oven functions refer to the “Using the 

Oven Controls” section of the USE AND CARE MANUAL.

8. If the oven is working properly, turn off the power supply to 

the oven.

9. Place the cover on the junction box and make sure the cover 

is securely fastened and turn on the power to the oven.

IMPORTANT

Leave these INSTALLATION instructions as well as the USE 
AND CARE MANUAL with the owner.

CONNECTING TO 208 VOLT CIRCUIT

This option is provided for areas where standard 240 Volt 
service is not available. This option must be accessed with the 
appliance connected to power source, and using the following 
sequence:

1. Within five minutes from power up, hold 

MENU

 and 

TIME

 

keys for 3 seconds to enter the user option menu. The 
display shows as follows:

2. Hold then 

TIME

 and 

LIGHT

 keys until the display becomes 

dark.

3. Hold 

MENU

 and 

LIGHT

 further, until the time display shows 

“Volt” and temperature module shows “240” blinking, 
waiting for an input.

4. Using 

+

 or 

-

 keys, the control toggles between 240V 

and 208V options. Hold 

MENU

 to confirm.

5. Hold 

TIME

 and 

LIGHT

 keys in order to quit the selection.

6. Hold 

MENU

 key for 3 seconds to quit the user option menu.

The voltage setting is stored and kept even after a long 
power-off.

Содержание 2OGG

Страница 1: ...2OGG 2OGS 304FICU INDUCTION AND DUAL FUEL RANGE WITH OVEN FOR RESIDENTIAL USE INSTRUCTIONS for installation...

Страница 2: ......

Страница 3: ...PART I INDUCTION SECTION DUAL FUEL SECTION INDUCTION SECTION...

Страница 4: ......

Страница 5: ...is manual for future reference Pay attention to these symbols present in this manual DANGER You can be killed or seriously injured if you don t IMMEDIATELY follow instructions WARNING This is the safe...

Страница 6: ...edition and all local codes and ordinances Copies of the standards listed may be obtained from National Fire Protection Association One Batterymarch Park Quincy Massachusetts 02269 CSA International...

Страница 7: ...760 29 29 32 524 20 5 8 1224 48 3 16 691 27 3 16 10 3 8 952 37 7 16 920 36 1 4 754 29 11 16 730 952 920 912 35 29 32 912 35 7 8 754 29 11 16 524 20 5 8 1224 48 3 16 691 10 730 28 23 32 60 GAS 1518 59...

Страница 8: ...r than 13 33 0 cm must be minimum 18 45 7 cm above cooking surface Wall cabinets directly above product must be a minimum of 30 76 2 cm above cooking surface Rear 0 with 3 7 6 cm backguard ADDITIONAL...

Страница 9: ...educe the weight considerably Due to the weight and size of the range and to reduce the risk of personal injury or damage to the product TWO PEOPLE ARE REQUIRED FOR PROPER INSTALLATION Anti Tip Bracke...

Страница 10: ...ir conditioning vents or fans IMPORTANT NOTE When installing against a combustible surface a minimum riser is required for a the range Follow all minimum clearances to combustible surfaces shown in th...

Страница 11: ...tion the appliance near its nal location as the legs are not suitable for moving the appliance over long distances Legs are packed in the cardboard top pack CAUTION Doors and passageways leading to th...

Страница 12: ...Adjust the leveling legs to the desired height and ensure range is level Turn the bottom section of each leg counter clockwise to raise the leg and clock wise to lower it Ensure floor is protected Sl...

Страница 13: ...with CSA Standard C22 1 Canadian Electrical Code Part 1 latest edition and all local codes and ordinances WARNING Risk of Electric Shock frame grounded to neutral of appliance through a link Groundin...

Страница 14: ...This wire must remain grounded to the appliance If cold water pipe is interrupted by plastic non metallic gaskets union connections or other insulating materials DO NOT use for grounding DO NOT ground...

Страница 15: ...metallic shielded copper cable or by means of a power supply cord kit Use only a power supply cord kit rated at 125 250 volts minimum and marked for use with ranges Cord must have either 3 or 4 conduc...

Страница 16: ...permit connecting chassis ground conductor to neutral wire of power supply cord 1 Feed the power supply cord through the strain relief in the cord conduit plate on bottom of range Allow enough slack...

Страница 17: ...d wires Black wires Cable from oven Bare or green wire A 4 WIREBRANCHCIRCUIT forUSonly Refer to Figure B Disconnect ground from neutral at free end of conduit Connect the green GROUND wire from the ra...

Страница 18: ...n lights preheat led will turn on A beep is sounded when the oven reaches the preset 350 F 175 C and the preheat light turn off Move the knob back to OFF position to stop cooking 7 To check the other...

Страница 19: ......

Страница 20: ......

Страница 21: ...PART II DUAL FUEL SECTION DUAL FUEL SECTION INDUCTION SECTION...

Страница 22: ......

Страница 23: ...reaker Fuse Box or Junction Box 22 9 Final checklist 23 IMPORTANT Save these instructions for the local electrical inspector use INSTALLER Please leave this manual with owner for future reference OWNE...

Страница 24: ...1 East Pleasant Valley Rd Cleveland OH 44131 5575 NOTE This range is manufactured for use with Natural gas or Propane To convert to LP propane or NG natural gas see instructions in the gas conversion...

Страница 25: ...16 730 952 920 912 35 29 32 912 35 7 8 754 29 11 16 524 20 5 8 1224 48 3 16 691 10 754 29 11 16 524 20 5 8 730 28 3 4 1224 48 3 16 1218 47 15 16 1218 47 31 32 691 10 952 920 730 28 23 32 60 GAS 1518 5...

Страница 26: ...with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 Minimum clearances Above cooking surface above 36 91 4 cm Sides 6 15 2 cm Within 6 15 2 cm side cl...

Страница 27: ...with a hood refer to the hood installation instructions for speci c hood clearances CAUTION These ranges weigh up to 530 pounds Some disassembly will reduce the weight considerably Due to the weight a...

Страница 28: ...en installing against a combustible surface a minimum riser is required for a the range Follow all minimum clearances to combustible surfaces shown in the illustration on the previous pages Before mov...

Страница 29: ...top of range and read them carefully before you begin CAUTION Standclear Theendsofthecutbandingmaysnaptowardyou 1 STEP 2 Open the top 2 and remove the accessories 3 then lift off the cardboard sheath...

Страница 30: ...ensure range is level Turn the bottom section of each leg counter clockwise to raise the leg and clockwise to lower it IMPORTANT When the unit first powers on it must complete a safety door lock test...

Страница 31: ...STEP 10 Hook tabs on bottom of toekick into slots on either side of the frame and rotate up until the magnets at the top of toekick make contact and hold it in place securely 4 Installation Instructi...

Страница 32: ...GAS SHUT OFF VALVE OPEN POSITION TO APPLIANCE GAS SUPPLY All supply piping except as noted should use common National Pipe Thread N P T For all pipe connections use an approved pipe joint compound re...

Страница 33: ...36 inch 3 Not approved for installation in a bedroom or a bathroom unless unit is direct vent Pressure Testing The appliance must be isolated from the gas supply piping system by closing its individua...

Страница 34: ...tructionsgiven Unless prohibited by local codes or ordinances a new A G A Certi ed exible metal appliance connector may be used to connect this appliance to its gas supply The connector must have an i...

Страница 35: ...s of the injector cover 2 5 Remove injector A by using a 9 32 nut driver counter clockwise 6 Remove injector B by using a 9 32 box wrench counter clockwise 7 Install the injectors supplied with this a...

Страница 36: ...each burner s ame at HI LO settings if the ame appears too large or too small make sure that all steps were completed correctly Pressure regulator conversion The appliances is designed for use with NG...

Страница 37: ...SITION NG DUAL FLAME RING 30 60 MAIN FLAME 192 SIMMER 72 MAIN FLAME 180 SIMMER 72 NG DUAL FLAME RING 36 MAIN FLAME 192 SIMMER 72 MAIN FLAME 180 SIMMER 72 NG DUAL FLAME RING GRIDDLE 48 MAIN FLAME 180 S...

Страница 38: ...nversion for LP or NG Gas INJECTORS POSITION LP DUAL FLAME RING 30 60 MAIN FLAME 105 SIMMER 50 LP DUAL FLAME RING 36 MAIN FLAME 105 SIMMER 50 LP DUAL FLAME RING GRIDDLE 48 MAIN FLAME 105 SIMMER 50 MAI...

Страница 39: ...cone of the ame please use caution Burns could result This appliance is shipped from the factory with low and medium ame settings adjusted If further adjustment is necessary proceed as follows Adjust...

Страница 40: ...ompleted correctly NOTE To obtain the correct minimum setting with LP gas turn clockwise tightening the valve s fully with the thin blade screwdriver into the recess behind control knob A and or B Ele...

Страница 41: ...ugh the neutral conductor For installations where grounding through the neutral conductor is prohibited Disconnect the ground from the neutral at free end of conduit Use grounding terminal or lead to...

Страница 42: ...etallic shielded copper cable or by means of a power supply cord kit Use only a power supply cord kit rated at 125 250 volts minimum and marked for use with ranges Cord must have either 3 or 4 conduct...

Страница 43: ...rmit connecting chassis ground conductor to neutral wire of power supply cord 1 Feed the power supply cord through the strain relief in the cord conduit plate on bottom of range Allow enough slack to...

Страница 44: ...IRCUIT forUSonly Refer to Figure B Disconnect ground from neutral at free end of conduit Connect the green GROUND wire from the range to the GROUND wire in the junction box bare or green colored wire...

Страница 45: ...n lights preheat led will turn on A beep is sounded when the oven reaches the preset 350 F 175 C and the preheat light turn off Move the knob back to OFF position to stop cooking 7 To check the other...

Страница 46: ...EN 24...

Страница 47: ......

Страница 48: ...us V 2 5 7 18 Via Della Torricella 29 Antella Bagno a Ripoli 50012 Florence Italy Tel 39 055 65 60 3324 39 055 62 18 07 Fax 39 055 62 06 70 officinegullo com info officinegullo com...

Отзывы: