4.1 Warning against unauthorised maintenance
−
Never exceed the permissible charging voltage!
−
Never exceed the permissible discharge current!
−
Only operate the battery within the specified temperature range.
−
Opening the battery is strictly forbidden and is reserved for trained employees or
service
providers to
be appointed
by us
.
−
Opening the battery leads to the expiration of warranty and guarantee
claims
against
Offgridtec
GmbH
.
−
In the event of technical faults or problems, always contact customer service with a
detailed
description of the fault,
as well as your customer and order number, by e-mail
to
.
50Ah / 100Ah / 150Ah / 200Ah
Offgridtec Smart-Pro 12,8V
4.2 Troubleshooting
The BMS interrupts the charging or discharging process in the following cases:
−
A
s soon as the voltage of a cell reaches more than 3.9V - the BMS switches the charge on
again as
soon as the
cell voltage reaches 3.6V
.
−
A
s soon as the voltage of a cell reaches less than 2V - the BMS allows a current drain again
as
soon as the
voltage reaches 2.5V
.
−
Switch-off due to overload - please refer to the specifications of the individual batteries,
sometimes
high starting
currents of capacitors in inverters or other consumers must be taken
into account --- the
overload lock is cancelled
8
seconds after the load is switched off
.
−
The charge/discharge process is interrupted when the battery temperature reaches 65
°
C - the
error
is
automatically cleared when the temperature reaches 50
°
C
.
−
If the maximum permissible pulse discharge current is exceeded, it is possible that the BMS
will find
the "Short
circuit" error in a continuous loop between "Short circuit" and "Short circuit
aborted".
If t
his error message does not
end itself, the battery function can be restored by
disconnecting the
loads and simply charging (>13.8V)
.
−
If an error is not automatically cleared and the battery remains in error mode, please send an
error
message to
[email protected], if necessary with screenshots from the app or other
meaningful
image material
.
General information
Offgridtec GmbH
Im Gewerbepark 11
84307 Eggenfelden
WEEE-Reg.-Nr. DE37551136
Contact information
Tel: 08721-7786187
Email: [email protected]
Web: www.offgridtec.com
CEO
: Christian & Martin Krannich
Account
Sparkasse Rottal-Inn
Account
: 10188985
BLZ: 74351430
IBAN: DE69743514300010188985
BIC: BYLADEM1EGF (Eggenfelden)
Seat and district court
HRB: 9179 Registergericht Landshut
Tax number:
141/134/30045
Ust-IdNr: DE287111500
Place of jurisdiction
: Mühldorf am Inn