background image

Содержание KEP

Страница 1: ...l Electric Self Contained Kettle Model KEP Oeveland Range Inc WITID Sf CANADA 1D31Mt1 5L 0eveIaIld 0Id0tWO GulDde cial e 216 411 wee AX cn6 411 3712 1177 XaInatD M r ar io c da UWlXC Pbaae 416 6 oCD6O fAX CG6 62W6 D KET 13 ...

Страница 2: ...t is built to comply with appIica b1e standards for manuf8cturers including UL AJ3 A NSF ASMEINtI Bd CSA CGA ETL and others _ BOILER Steam Generator MAINTENANCE IS THE RESPONSIBILITY OF THE ONNE9 USER AND IS NOT C RED BY THIS WARRANTY The use c A good Quality feed WIlIer is the responsibility tJ the Owner User see e Water Requitemenls below THE USE OF POOR QUALITY FEED WATER WILL VOID EQUIPMENT WA...

Страница 3: ...operating Instructions section of this manual When lit indicates that the kettle heating elements are on Cycles On Off with thermostat controL When lit indicates that the heating elements have cut out and the unit requires more water See Reservoir Fill procedure Indicates steam pressure In PSI inside the steam jacket as well as vacuum in inches of mercury In the unlikely event that there is an exc...

Страница 4: ...y Valve 55 PSI 1 Blow Down Tube 1 Toggle Switch 1 LED Green 1 Rubber Boot 1 Potentiometer 1 Knob 1 LED Red 1 Safety Thermostat 1 Pressure Guage 1 Thermistor 1 Rotary Seal 1 Description Oty Use only replacement pans which are factory SUpplied as to preserve the certification of UndefWriters Laboratories American Gas Association Canadian Standards AsSOCiation or Canadian Gas Association as applicabl...

Страница 5: ...KE51226 Connector Pin 1 7 KE50376 Terminal Block End section 1 8 KE50377 Terminal Block section 3 Use only replacement parts which are faclDry supplied as to preserve the certification of Underwriters Laboratories American Gas Association C8nlIdian Standards Association or canadian Gas Association as applicable The use of other than factory supplied replacement par1S will voidthe warranty ...

Страница 6: ...st End Piece Screws Adjust Bolts End Block Spring 40 gal and under Spring 60 gal and over Cylinder Knob Ball Type Cover Handle Specify Model Lid Holder Washer lid Holder Bolt Lid Holder Qty 1 1 1 1 1 1 2 2 1 1 1 1 1 1 1 1 Use only replacement parts whieh are factory supplied as to preserve the certification of Underwriters Laboratories American Gas Association Canadian Standards Association or Can...

Страница 7: ...ease order hem no 1 7 Part no KE50972 Body 3 N A Please order Item no 1 7 Part no KE50973 0 Ring 1 h 2 W 1 OW Ring 3 1 Stem 1 2 1 Stem 2 1 Stem 3 1 Bonnet 1 12 1 Bonnet 2 1 Bonnet 3 1 Hex Nut 1 V2 1 Hex Nut 2 W 1 Hex Nut 3 1 Knob 1 h 2 1 Knob 3 1 Wing Nut 1 12 2 1 Acorn NUl 3 1 use only replacement pans whICh are factory supplied as to preserve the certification of Underwnters Laboratones AmerIcan...

Страница 8: ...ingle Pantry Control Valve please order Item No 4 5 6 7 9 Old Style Double Pantry Control Valve please order Item No 4 5 6 7 10 1 Spout please order Item No 4 5 6 7 14 0 Ring Adapter to adapt new style spout to old style control valve 1 2 1 d I B A L A B Part No 4 8 KES0833 10 9 KES0832 6 22 KES0831 12W 14 KES0830 1 3 4 14 KES0829 S 14 KES0828 24 9 KES0827 20 9 KES0826 12Y2 9 KES082S Use only repl...

Страница 9: ...KETTLE AND SKILLET FAUCET New Style 31 in Spout Single Faucet 3 Old Style 1in Spout I I I ...

Страница 10: ...ective contactorls Fault Isolation Procedure Step Test Resuh Remedy 1 Is there proper incoming voltage at terminal Yes Go to step 2 block No Correct external power supply problem 2 Is the red LED illuminated Yes Follow Kettle Filling Procedure If thiS does not correct the problem go to PROBLEM 0 No Go to step 3 3 Is the green LED illuminated Yes Go to step 4 No Go to step 7 4 Do both contactors en...

Страница 11: ...box Replace defective thermistor B Problem Kettle heats too slowly or not hot enough Note normal max operating pressure with an empty kettle is 30 35 psL Possible Causes 1 Air in kettle jacket requires venting 5 Defective contactors 2 Defective safety thermostat 6 Defective control box 3 Defective potentiometer 7 Defective element s 4 Defective thermistor Fault ISOlation Procedure Step Test Result...

Страница 12: ...efective thermistor 2 Defective potentiometer 3 Defective 12 VDC relay 4 Defective control box Fault 180lation Procedure Step Test 1 Does the green LED turn off even though the contactors remain energized 2 Unplug the control box and measure the resistance across the potentiometer Is the resistance approx 0 ohms at max and 50 000 ohms at min settings 3 Remove kettle thermistor and allow to cool Re...

Страница 13: ... a pin approximately in the hole where the first slotted screw was removed from 5 Remove second slotted screw 6 While holding Allen wrench remove pin 7 Tum Allen wrench clockwise to tighten or counter clockwise to loosen tension to produce desired effect 8 Re insert pin in one of the two holes 9 Tighten one slotted screw in the other hole it may be necessary to turn Allen wrench slightly to align ...

Страница 14: ...T INDICATOR 31 LOW WollTEI lINDICoCI OR 41 PROBE sl L HEAT RELAY 6 GROUND 7 16 Ii DC 16 VAC 6 V AC 11 Il OIlEl SSK SClUD STATE CONTROl CLASS 2 1 RAN9FtlIMR MO V AI 1 1 I B __2PR08 EC _ 1 B I t 9 1 16 Ii AC BD5F l Cll JIlED i YEU DW LACK I I LI L2 1 3 Single Three Phase Phase ...

Страница 15: ...k WARNING The fused disconnect switch must be switched off before removing the kettle s bottom cover which exposes dangerous high voltage RESERVOIR FILL PROCEDURES The reservoir s water level must be maintained at the proper level to submerge the heater elements Under normal operating conditions the sealed water reservoir should never require the addition of water If the red low water light comes ...